Edison 15.5CAVH1E CAVH Current Limiting Potential Transformer Fuse, 1 A, 15500 VAC, 80 kA Interrupt, Class E
Medium Voltage Fuse
656051
MFG #: 15.5CAVH1E
Bussmann
648.52000
/ ea
- Alternate Catalog Number: 15.5CAVH1E
- Amperage Rating: 1 A
- Application: Utility - Substations, Utility Transmission and DistributionUtility
- ARRA Compliant: C
- Body Size: 1.63 in Dia x 12.87 in L
- Buy American Compliant: C
- Catalog Number: 15.5CAVH1E
- Class: Class back-up
- Connection: Ferrule end x ferrule end
- Country of Origin: IN
- Currency: USD
- EU RoHS Indicator: C
- Gross Weight Per Pack: 0.14468125 lb
- Gross Weight per Pack Metric: 5.30
- Harmonization Tariff Schedule Code: 8536100040
- Height: 1.61 in
- Height [Metric]: 4.1001 cm
- Indicating|Non~Indicating: Indicating
- Interrupt Rating: 80 kAIC kA
- Length: 12.91 in
- Length [Metric]: 32.8000 cm
- Mounting: Bolt-On
- Mounting Type: Bolt-On
- Response Time: 1E
- Series: CAVH
- Size: 1.63 In Diameter X 12.87 In Length
- Standard: Contact factory
- Standards: ARRA CompliantBuy American Act CompliantRoHS CompliantBS2692-1IEC60282-1
- Sub Brand: Bussmann Series
- Terminal Type: Ferrule
- Type: Medium voltage auxiliary fuse
- UNSPSC: 39121626
- UPC 11: 05171283116
- UPC 12: 051712831161
- Voltage Rating: 15,500 V
- Width: 1.61 In
- Width [Metric]: 4.1001 cm
- Stock Status: NONSTOCK
- Brand: Bussmann
- Manufacturer: Eaton
- Applications
- Features
Utility - Substations, Utility Transmission and DistributionUtility |
Low amp, current limiting e-rated PT medium voltage fuses are general purpose fuses defined by their melting time current characteristic that permit their electrical interchangeability with other fuses of the same E-rating |
E-rated general purpose fuses must have a current responsive element that will melt in 300 sec at an rms current within the range of 200% to 240% of the fuses nameplate current rating, fuse refill or link per ANSI C37.46 for fuses rated 100E or less |
PT fuses are physically dimensioned for easy installation in existing hardware |
Space saving size eases design considerations for new installations |
Current limiting fuses provide positive interruption even on low fault currents |
The fuse limits the magnitude of electromechanical stresses in the protected apparatus |
These fuses are in a self-contained, non-venting package for installation indoors or outdoors in an enclosure |
Open fuse indicator speeds troubleshooting by providing a positive visual indication of fuse operation |
Fitted with a striker pin for indication |