Bussmann® KRP-C-1000SP Low-Peak™ KRP-C Current Limiting Time Delay Fuse, 1000 A, 600 VAC/300 VDC, 300/100 kA Interrupt, Class L
Class L Fuses
44251
MFG #: KRP-C-1000SP
Bussmann
709.03000
/ ea
- Alternate Catalog Number: KRP-C-1000SP
- Application: Ind Facilities & Factories - Facility: Safety and Security Systems
- ARRA Compliant: C
- Body Size: 2-1/2 in Dia x 10-3/4 in L
- Buy American Compliant: C
- Catalog Number: KRP-C-1000SP
- Connection: Bolted Blade End X Bolted Blade End
- Country of Origin: MX
- Currency: USD
- Element: Dual
- EU RoHS Indicator: C
- Gross Weight Per Pack: 4.2000 lb
- Gross Weight per Pack Metric: 1.90
- Gross Weight UOM Metric: kg
- Harmonization Tariff Schedule Code: 8536100040
- Height: 2.90 in
- Height [Metric]: 7.3660 cm
- Length: 11.70 in
- Length [Metric]: 29.7180 cm
- Material: Melamine Glass Tube
- Mounting Type: Bolt-On
- Response Time: 4 sec at 500%
- Series: KRP-C
- Size: 2.50 In Diameter X 10.75 In Length
- Standard: RoHS Compliant,CE Marked
- Standards: ARRA CompliantBuy American Act CompliantRoHS CompliantGuide No. JDDZUL File No. E4273CSA Class 1422-02CSA File No. 53787Class L per CSA C22.2CSA File No. 248.10CE Certified
- Sub Brand: Bussmann Series
- Terminal Type: Knife Blade
- Type: Fuse
- UNSPSC: 39121626
- UPC 11: 05171260510
- UPC 12: 051712605106
- Width: 2.80 in
- Width [Metric]: 7.1120 cm
- Stock Status: NONSTOCK
- Brand: Bussmann
- Manufacturer: Eaton
- Amperage Rating: 1k A
- Class: L
- Interrupt Rating: 300 kAIC at 600 Vac100 kAIC Vdc
- Voltage Rating: 600//300 VAC//VDC
Eaton's Bussmann series low peak ultimate protection fuses are the industry's only UL® Listed and CSA Certified fuses with a 300kA interrupting rating, providing 50% more protection than any other listed fuse*. The high interrupting rating allows for simple, worry-free installation in virtually any application. low peak fuses are available in Class CC, CF, J, L and RK1, so there is a fuse to meet the vast majority of 600V over current protection needs. Plus, when upgrading to low peak fuses, existing fuse inventory can be reduced by up to fuse.
- Brochure URL - COBUSSE01827_26.pdf(Brochure URL)
- Catalog URL - IDW_DOCUMENT_e3c073e59124bc09d90d847f6b0b83d8a00b926d72ad1c2e4c4e57888ba92dd8.pdf(Catalog URL)
- Spec Sheet 2 URL - IDW_DOCUMENT_1537664612367.pdf(Spec Sheet 2 URL)
- Spec Sheet URL - 10973_X6COT48DLNEYJV1U.pdf(Spec Sheet URL)
- http://www.bussmann.com(Seller Home Page URL)
- Spec Sheet 1 URL - Bussmann_KRP_C_1900SP_Specification_Sheet_1.pdf(Spec Sheet 1 URL)
- Tech Bulletin URL - datasheet.php?model=FNQ-30&locale=en_GB(Tech Bulletin URL)
- Tech Drawing URL - bus-ele-cat-1007-01-lv-branch-fuses.pdf(Tech Drawing URL)
- Video - https://www.youtube.com/embed/YMvqUyoETXk(Video)
- Applications
- Features
Ind Facilities & Factories - Facility: Safety and Security Systems |
Silver Plated End Bell |
Fast short circuit protection with time-delay performance provide ultimate protection |
Consistent 2: 1 ampacity ratios for all low peak fuses make selective coordination easy |
Current-limiting action of the fuse generally affords considerable reduction in bus bracing |
All purpose silver-linked fuse for both overload and short circuit protection for high capacity systems |
O-ring seals maximize pressure build-up during current-limiting action and ensure filter retention |
High-grade silica sand filler accelerates response of fuse to short circuits by having quenching effect on the fuse arc |
99.9 percent pure silver links provide low watt loss with low operating temperature on normal current levels and minimizes total clearing IT fault energy left-through |
300 kA (RMS symmetrical) at 600 VAC/100 kA at 300 VDC interrupt rating |