Bussmann® FNQ-R-15 LIMITRON™ FNQ-R Current Limiting Time Delay Fuse, 15 A, 600 VAC/300 VDC, 200/20 kA Interrupt, Class CC

Class CC Fuses
69129 MFG #: FNQ-R-15
Bussmann
43.01000 / ea
  • Alternate Catalog Number: FNQ-R-15
  • Application: Ind Facilities & Factories - Facility: Safety and Security Systems
  • ARRA Compliant: C
  • Buy American Compliant: C
  • Catalog Number: FNQ-R-15
  • Connection: Ferrule end x ferrule end
  • Country of Origin: MX
  • Currency: USD
  • EU RoHS Indicator: C
  • Gross Weight Per Pack: 0.0250 lb
  • Gross Weight per Pack Metric: 0.01
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536100040
  • Height: 1.50 in
  • Height [Metric]: 3.8100 cm
  • Length: 0.41 in
  • Length [Metric]: 1.0414 cm
  • Material: Melamine tube
  • Response Time: 12 S at 200%
  • Size: 13/32 In Diameter X 1-1/2 In Length
  • Standard: RoHS Compliant,CE Marked
  • Standards: ARRA CompliantBuy American Act CompliantRoHS CompliantUL 248-4Guide JDDZUL File No. E4273CSA Class 1422-01CSA File No. 53787-HRC-MISCCE Certified
  • Sub Brand: Bussmann Series
  • Type: Fuse
  • UNSPSC: 39121606
  • UPC 11: 05171249711
  • UPC 12: 051712497114
  • Width: 0.41 in
  • Width [Metric]: 1.0414 cm
  • Stock Status: NORMALLY STOCKED
  • Brand: Bussmann
  • Manufacturer: Eaton
  • Amperage Rating: 15 A
  • Class: CC
  • Interrupt Rating: 200 kAIC at 600 Vac20 kAIC at 300 Vdc
  • Voltage Rating: 600//300 VAC//VDC
QTY
  • Applications
  • Features
Ind Facilities & Factories - Facility: Safety and Security Systems
Rejection style
Provides 10X better current limitation to help prevent equipment damage caused by short circuit events
200 kA interrupting rating complies with NEC Section 110.9 for todays large capacity systems
Fast-acting fuse helps prevent equipment damage caused by short circuit events
Rejection type fuse fits both standard and rejection-style holders
The Class CC FNQ-R Limitron fuse meets the needs of control circuit transformer protection
FNQ-R fuses can be sized according to NEC and UL requirements and still allow the high inrush currents, with significantly more time-delay than the UL minimum value of 12 seconds at 200% for Class CC fuses
Nickel plated brass end cap
200 kA AC (RMS symmetrical)