Bussmann® FNQ-R-10 LIMITRON™ FNQ-R Current Limiting Time Delay Fuse, 10 A, 600 VAC, 200 kA Interrupt, Class CC, Cylindrical Body
Class CC Fuses
5070
MFG #: FNQ-R-10
Bussmann
45.60000
/ ea
- Alternate Catalog Number: FNQ-R-10
- Application: Ind Facilities & Factories - Facility: Safety and Security Systems
- ARRA Compliant: C
- Buy American Compliant: C
- Catalog Number: FNQ-R-10
- Connection: Ferrule end x ferrule end
- Country of Origin: MX
- Currency: USD
- EU RoHS Indicator: C
- Gross Weight Per Pack: 0.0050 lb
- Gross Weight per Pack Metric: 0.07
- Gross Weight UOM Metric: kg
- Harmonization Tariff Schedule Code: 8536100040
- Height: 1.50 in
- Height [Metric]: 3.8100 cm
- Length: 1.50 in
- Length [Metric]: 3.8100 cm
- Material: Melamine tube
- Response Time: 12 S at 200%
- Size: 13/32 In Diameter X 1-1/2 In Length
- Standard: RoHS Compliant,CE Marked
- Standards: UL 248-4, Guide No. JDDZ, File No. E4273, CSA Class 1422-01, File No. 53787-HRC-MISC, CE Certified, RoHS Compliant
- Sub Brand: Bussmann Series
- Type: Fuse
- UNSPSC: 39121606
- UPC 11: 05171249709
- UPC 12: 051712497091
- Width: 0.41 in
- Width [Metric]: 1.0414 cm
- Stock Status: NORMALLY STOCKED
- Brand: Bussmann
- Manufacturer: Eaton
- Amperage Rating: 10 A
- Class: CC
- Interrupt Rating: 200 kAIC
- Voltage Rating: 600 V
- Brochure URL - COBUSSE01827_18.pdf(Brochure URL)
- http://www.bussmann.com(Seller Home Page URL)
- Spec Sheet 1 URL - Bussmann_FNQ_R_1_Datasheet_1.pdf(Spec Sheet 1 URL)
- Spec Sheet URL - 10973_1CHO8UWEZL94QBSP.pdf(Spec Sheet URL)
- Spec Sheet URL - FNQ-R-10(Spec Sheet URL)
- Spec Sheet URL - skuPage.FNQ-R-10.pdf(Spec Sheet URL)
- Tech Bulletin URL - datasheet.php?model=FNQ-30&locale=en_GB(Tech Bulletin URL)
- Tech Drawing URL - Bus_Ele_DS_1012_FNQ.pdf(Tech Drawing URL)
- Video - https://www.youtube.com/embed/YMvqUyoETXk(Video)
- Applications
- Features
Ind Facilities & Factories - Facility: Safety and Security Systems |
Rejection style |
Provides 10X better current limitation to help prevent equipment damage caused by short circuit events |
200 kA interrupting rating complies with NEC Section 110.9 for todays large capacity systems |
Fast-acting fuse helps prevent equipment damage caused by short circuit events |
Rejection type fuse fits both standard and rejection-style holders |
The Class CC FNQ-R Limitron fuse meets the needs of control circuit transformer protection |
FNQ-R fuses can be sized according to NEC and UL requirements and still allow the high inrush currents, with significantly more time-delay than the UL minimum value of 12 seconds at 200% for Class CC fuses |
Nickel plated brass end cap |
200 kA AC (RMS symmetrical) |