Edison TCF90 CUBEFuse TCF Time Delay Fuse, 90 A, 600 VAC/300 VDC, 300/100 kA, Class CF, Square Body

Cube Shaped Fuses
178374 MFG #: TCF90
Bussmann
315.06000 / ea
  • Alternate Catalog Number: TCF90
  • ARRA Compliant: C
  • Buy American Compliant: C
  • Catalog Number: TCF90
  • Connection: Blade end
  • Country of Origin: MUL
  • Currency: USD
  • Element: Dual
  • EU RoHS Indicator: C
  • Gross Weight Per Pack: 0.3000 lb
  • Gross Weight per Pack Metric: 4.76
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536100040
  • Height: 2.28 in
  • Height [Metric]: 5.7988 cm
  • Length: 3.07 in
  • Length [Metric]: 7.8003 cm
  • Material: Glass filled PES
  • Mounting: 35 mm Din Rail, chassis
  • Response Time: 10 S at 500%
  • Size: 3.01 In Length X 1.00 In Height
  • Standard: CSA Certified ,UL Listed,CE Marked,RoHS Compliant
  • Standards: CE Certified, UL Guide JFHR, File No. E4273, CSA Class 1422- 02, File No. 53787, RoHS Compliant
  • Sub Brand: Bussmann Series
  • Type: Fuse
  • UNSPSC: 39121606
  • UPC 11: 05171261817
  • UPC 12: 051712618175
  • Width: 6.10 in
  • Width [Metric]: 15.4991 cm
  • Stock Status: NONSTOCK
  • Brand: Bussmann
  • Manufacturer: Eaton
  • Amperage Rating: 90 A
  • Class: Class CF
  • Interrupt Rating: 300 kAIC at 600 Vac100 kAIC at 300 Vdc
  • Voltage Rating: 600//300 VAC//VDC
QTY
  • Applications
  • Features
Ind Facilities & Factories - Facility: Safety and Security SystemsDatacenters - Facilities: Power DistributionCommercial / Institutional Buildings / Structures - Critical PowerInd Facilities & Factories - Facility: Power Distribution and ControlStationary Machinery and Equipment Outside Factory - HVAC
Finger safe
Worlds first finger-safe power fuse system
Smallest footprint of any class fuse including class J, CC, T and RK
Meets class CF and class J time delay electrical performance requirements
Available with and without open fuse indication
Indicating version features easyID open fuse technology for faster troubleshooting and reduced downtime
Faster response to damaging faults to help reduce destructive thermal and magnetic forces
Long time delay minimizes nuisance circuit openings due to temporary overloads and transient surges
High interrupting rating to safely interrupt faults up to 300kA
No venting of arc or molten metal and gases during opening
Robust cycling and inrush current withstand
Low let-through currents under fault conditions
Provides type 2 no damage in protection for IEC motors starters when properly sized
Easy selective coordination with any other Cooper Bussmann Low-Peak class CC, L, J and RK1 fuse with simple 2: 1 amp ration between upstream and downstream fuses
-40 to 80 deg C operating temperature
300 kA RMS symmetrical (UL) and 300 kA RMS symmetrical (CSA) at 600 VAC, 100 kA (UL and CSA) at 300 VDC interrupt rating
Copper alloy terminals, Electroless tin terminal plating, PES (Polyethersulfone) indicator lens, energetic chemical indicator
10 sec at 500% response time