Edison CUBEFuse TCF Time Delay Fuse, 80 A, 600 VAC/300 VDC, 300/100 kA, Class CF, Square Body

Cube Shaped Fuses
1107058 MFG #: TCF80RN
Bussmann
199.66000 / ea
  • Alternate Catalog Number: TCF80RN
  • ARRA Compliant: C
  • Body Size: 3 in L x 1 in W x 1 in H
  • Buy American Compliant: C
  • Catalog Number: TCF80RN
  • Color: Black
  • Connection: Blade end
  • Country of Origin: MUL
  • Currency: USD
  • Element: Dual
  • EU RoHS Indicator: C
  • Frequency Rating: 50 to 60
  • Gross Weight Per Pack: 1.6460 lb
  • Gross Weight per Pack Metric: 0.80
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536100040
  • Height: 2.28 in
  • Height [Metric]: 5.7988 cm
  • Length: 3.07 in
  • Length [Metric]: 7.8003 cm
  • Material: Glass filled PES
  • Mounting: 35 mm Din Rail, chassis
  • Mounting Type: Chassis/DIN Rail
  • Response Time: 10 S at 500%
  • Series: TCFRN
  • Standard: UL Listed ,CSA Certified,CE Marked,RoHS Compliant
  • Standards: ARRA CompliantBuy American Act CompliantRoHS 2011/65/EUUL Guide No. JFHR File No. E4273CSA Class 1422- 02 File No. 53787CE CertifiedIEC 60529
  • Sub Brand: Bussmann Series
  • Terminal Type: Radial Blade Plug-In
  • Type: Fuse
  • UNSPSC: 39121606
  • UPC 11: 05171223617
  • UPC 12: 051712236171
  • Width: 6.10 in
  • Width [Metric]: 15.4991 cm
  • Stock Status: NONSTOCK
  • Brand: Bussmann
  • Manufacturer: Eaton
  • Amperage Rating: 80 A
  • Class: Class CF
  • Interrupt Rating: 300 kAIC at 600 Vac100 kAIC at 300 Vdc
  • Voltage Rating: 600//300 VAC//VDC
QTY
  • Applications
  • Features
Ind Facilities & Factories - Facility: Safety and Security SystemsDatacenters - Facilities: Power DistributionCommercial / Institutional Buildings / Structures - Critical PowerInd Facilities & Factories - Facility: Power Distribution and ControlStationary Machinery and Equipment Outside Factory - HVAC
Finger safe
10 s (minimum) at 500% rated current response time
300 kA RMS symmetrical UL, 200 kA RMS symmetrical CSA, 100 kA DC UL/CSA rated interrupt rating
Separate overload and short circuit elements provide time delay for sizing of high inrush loads linked with class J current limitation
Selective coordination ratio of 2:1 (within Low-Peak™ fuse family) prevents electrical shutdowns from extending beyond the failed circuit
Smallest footprint of any class CC, J, T or RK fuse provides substantial space savings and installation flexibility
IEC 60529 and finger safe rating provides enhanced workplace safety
High 300 kA interrupt rating safely interrupts virtually any fault
No venting of arc or molten metal and gases during opening
Robust cycling and inrush current withstand
Low let through currents under fault conditions
Provides type 2 "No Damage" in protection for IEC motors starters when properly sized
Easy selective coordination with any other Bussmann series Low-Peak® class CC, J, L or RK1 fuse with simple 2:1 amp ratio between upstream and downstream fuses
Easy selective coordination with any other Cooper Bussmann Low-Peak class CC, L, J and RK1 fuse with simple 2: 1 amp ration between upstream and downstream fuses
-40 to 80 deg C operating temperature
300 kA RMS symmetrical (UL) and 300 kA RMS symmetrical (CSA) at 600 VAC, 100 kA (UL and CSA) at 300 VDC interrupt rating
Copper alloy terminals, Electroless tin terminal plating, energetic chemical indicator
10 sec at 500% response time