Appleton® GUBB-22 Unilets™ GUBB Explosionproof Junction Box, 10 in L x 8 in W x 6.88 in D, NEMA 7BCD/9EFG, Malleable Iron

Hazardous Location Junction Boxes
196802 MFG #: GUBB22
Appleton™
1191.17000 / ea
  • Application: For Use With Unilets Threaded Metal Conduit
  • ARRA Compliant: C
  • Buy American Compliant: Y
  • Capacity: 224 in³
  • Catalog Number: GUBB22
  • Country of Origin: US
  • Cubic Capacity: 224 CU-IN in³
  • Currency: USD
  • EU RoHS Indicator: C
  • Finish: Triple Coated
  • Gross Weight Per Pack: 43.7000 lb
  • Gross Weight per Pack Metric: 19.82
  • Gross Weight UOM Metric: kg
  • Height [Metric]: 21.0820 cm
  • Length [Metric]: 32.0040 cm
  • Mounting: Lugs
  • Mounting Type: Lug
  • Series: GUBB
  • Size: 7.19 IN Cover Opening
  • Standard: UL 886 (UL 1203), UL File Number E10444, CSA C22.2 No. 25, C22.2 No. 30, 025875 Certified, Class I, Division 1 And 2, Groups B, C, D, Class II, Division 1 And 2, Groups E, F, G, Class III, NEMA 7BCD, 9EFG
  • Standards: ARRABuy American ActRoHS CompliantUL 886UL 1203UL File No. E10444CSA C22.2 No. 25, C22.2 No. 30CSA File No. 025875NEC/CEC Class I, Division 1 and 2, Groups B, C, D, Class II, Division 1 and 2, Groups E, F, G, Class III
  • Sub Brand: UNILETS
  • Type: Dust-Ignitionproof Explosionproof
  • UNSPSC: 39121332
  • UPC 11: 78138132446
  • UPC 12: 781381324465
  • Width [Metric]: 26.9240 cm
  • Stock Status: NONSTOCK
  • Brand: Appleton™
  • Manufacturer: Appleton
  • Depth: 6.88 in
  • Height: 8.30 in
  • Length: 12.60 in
  • Material: Malleable Iron
  • NEMA Rating: NEMA 3/3R/4/7BCD/9EFG
  • Width: 10.60 in
QTY
  • Applications
  • Features
For Use With Unilets Threaded Metal Conduit
Provided with mounting lugs; Furnished with covers; Wide selection of sizes and locations for drilled and tapped conduit openings; Suitable for use as an enclosure for relays, instrument and other control apparatus in classified locations; Explosionproof; Dust-ignitionproof; Ideal where number and size of conductors require a junction box with additional space; Drilled and tapped openings from 1/2 IN through 4 IN as specified
All conduit hubs and openings provide a minimum of five full threads to meet UL requirements
Accurately tapped, tapered conduit threads provide tight, rigid joints and ground continuity
Wide selection of sizes and locations for drilled and tapped conduit openings
Suitable for use as an enclosure for relays, instrument and other control apparatus in classified locations
O-rings standard to provide raintight fit
Chromate/epoxy powder coated/zinc electroplated finish
Ideal where number and size of conductors require a junction box with additional space
7.19 in cover opening
2 form number
Triple-coat (1) zinc electroplate, (2) chromate, and (3) epoxy powder coat
Used with unilets threaded metal conduit
Class I, Division 1 and 2, Groups B, C, D, Class II, Division 1 and 2, Groups E, F, G, Class III, NEMA 7BCD, 9EFG