Schneider Electric Altivar 212 ATV212HD15N4 Variable Speed Drive With Heat Sink, 480 VAC, 22.8/28.5 A, 20 hp, 9.65 in W
AC Drives
664427
MFG #: ATV212HD15N4
Schneider Electric
2262.19000
/ ea
- Alternate Catalog Number: ATV212HD15N4
- Application: Asynchronous motors;Pumps and fans in HVAC;
- ARRA Compliant: N
- Buy American Compliant: N
- Catalog Number: ATV212HD15N4
- Control: +/- 10 OF NOMINAL SLIP 0.2 TN TO TN
- Country of Origin: ID
- Currency: USD
- Display: for DC bus energized 1 LED (red)
- Display Type: Analog
- Enclosure: OPEN IP20
- Enclosure Type: Open/IP20/IP21/IP41
- Environmental Conditions: -10-40 A°C WITHOUT)-40-50 A°C WITH DERATING FACTOR),CLASSES 3C1 IEC 60721-3-3-CLASSES 3S2 IEC 60721-3-3
- EU RoHS Indicator: Y
- Gross Volume Per Pack: 2111.96
- Gross Volume per Pack Metric: 34608.69
- Gross Volume UOM: CI
- Gross Volume UOM Metric: cm3
- Gross Weight Per Pack: 25.4400 lb
- Gross Weight per Pack Metric: 11.54
- Gross Weight UOM Metric: kg
- Harmonization Tariff Schedule Code: 8504404000
- Height: 27.5000 in
- Height [Metric]: 75.0000 cm
- Input Voltage: 380...480 V - 15...10 %
- Item Group: 22157
- Length: 30.0000 in
- Length [Metric]: 80.0000 cm
- Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=61737718&lang=en-us
- Number Of Phases: 3
- Power Rating: 625 W
- Returnable: Y
- Size: 190 MM,245 MM,330 MM in
- Standard: IP21
- Sub Brand: ATV212
- Substitute Product Catalog Number: VW3A1101
- Type: 3-Phase
- UNSPSC: 39122001
- UPC 11: 78590194408
- UPC 12: 785901944089
- Warranty Description: Contractual Warranty:18 months
- Width [Metric]: 60.0000 cm
- Stock Status: NONSTOCK
- Brand: Schneider Electric
- Manufacturer: Schneider Electric
- Amperage Rating: 22.8/28.5 A
- Depth: 7.48 in
- Horsepower: 20 hp
- Voltage Rating: 400/480 VAC
- Width: 39.5000 in
- Brochure URL - 11003_C9XPMSHBGA4Q63U2.pdf(Brochure URL)
- Catalog URL - IDW_DOCUMENT_4859d10e329e1f501e78e29ede384b77ea0438684e32eb314b494a1f75dc387c.pdf(Catalog URL)
- Computer~Aided [CAD|BIM] Model URL(Computer~Aided [CAD|BIM] Model URL)
- Install Instructions 1 URL - 11003_4Z82BVXWAQU3KTSF.pdf(Install Instructions 1 URL)
- Line Drawing URL(Line Drawing URL)
- Seller Home Page URL - us(Seller Home Page URL)
- Service Manual URL - 11003_LDVUHNM7KYXQZGJ0.pdf(Service Manual URL)
- Spec Sheet 1 URL - Schneider_Electric_ATV212HD15N4_Datasheet.pdf(Spec Sheet 1 URL)
- Spec Sheet URL - 11003_7FGC6093YLN1MTPR.pdf(Spec Sheet URL)
- Video - https://www.youtube.com/embed/J7XR8eaHfK4(Video)
- User Manual URL - 11003_K0F4R39OPIHZUMLD.pdf(User Manual URL)
- Tech Bulletin URL - 11003_XY5MQ9LBZ4J1W7FO.pdf(Tech Bulletin URL)
- Video - https://www.youtube.com/embed/vpIAZcgf9po(Video)
- Tech Drawing URL - sales?sn=ATV212HD15N4(Tech Drawing URL)
- Applications
- Features
Asynchronous motors;Pumps and fans in HVAC; |
VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14;L1/R, L2/S, L3/T terminal 25-25 mm² / AWG 3;Flux vector control without sensor, standard;voltage/frequency ratio, 2 points;voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo);voltage/frequency ratio - Energy Saving, quadratic U/f;voltage/frequency ratio, 5 points;Overheating protection drive;line supply undervoltage drive;against input phase loss drive;thermal protection motor;motor phase break motor;with PTC probes motor;thermal power stage drive;short-circuit between motor phases drive;input phase breaks drive;overcurrent between output phases and earth drive;overvoltages on the DC bus drive;break on the control circuit drive;against exceeding limit speed drive;line supply overvoltage and undervoltage drive;Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection;internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection |
Centralized technical management |
Centered on user-friendliness |
Centered on protection |
APOGEE FLN, BACnet, LonWorks, METASYS N2, Modbus optional communication card |
Electrical between power and control insulation |
Maximum output voltage equal to input voltage 3-phase output |
12 to 16 kHz with derating factor switching frequency |
6 to 16 kHz adjustable switching frequency |
1 to 10 speed range |
625 W power dissipation |
54420.42 Gal/hr air flow |
54 dB noise level |
Electrical between power and control insulation |
323 to 528 VAC supply voltage limits |