O-Z/Gedney EYA-600 6 IN HOR/VERT SEALING F

Explosion Proof Conduit Sealing Fittings
475591 MFG #: EYA600
O-Z/Gedney
1538.97000 / ea
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Catalog Number: EYA600
  • Country of Origin: MX
  • Currency: USD
  • Dimensions: 12-1/8 in L x 7.31 in W
  • EU RoHS Indicator: N
  • Gross Weight Per Pack: 32.7000 lb
  • Gross Weight per Pack Metric: 14.83
  • Gross Weight UOM Metric: kg
  • Height: 9.30 in
  • Height [Metric]: 23.6220 cm
  • Length: 21.40 in
  • Length [Metric]: 54.3560 cm
  • Standards: CEC Class I Division 1 and 2 Groups B, C, D, Class I Zone 1 and 2 Groups IIA, IIB, Class II Division 1 and 2 Groups E, F, G, Class IIINEC 500/503/505CSA 009795/C22.2 No. 30Military Specification Mil-F-28675UL 886/E-10444/E-34997
  • Type: Vertical/Horizontal Female
  • UNSPSC: 39121311
  • UPC 11: 78312613820
  • UPC 12: 783126138207
  • Width: 7.50 in
  • Width [Metric]: 19.0500 cm
  • Stock Status: NONSTOCK
  • Brand: O-Z/Gedney
  • Manufacturer: O-Z/Gedney
  • Finish: Electro-Zinc Plated/Polished Chrome/Epoxy Powder Coated
  • Material: Malleable Iron
  • Size: 6 in
  • Suitable For Use With: Threaded RMC and IMC Conduit
Explosionproof Conduit Sealing Fitting, Turning Radius 7-3/8 Inch, Trade Size 6 Inch, Connection Type Female, Female, Material Zinc Electroplated Chromate Epoxy Powder Coated Malleable Iron, Mounting Position Horizontal/Vertical, Enclosure Class I Div 1 and 2 Group B C D, Class I Zone 1 and 2 Group IIA IIB, Class II Div 1 and 2 Group E F G, Class III, Approval UL 886, CSA C22.2, Overall Length 12-1/8 Inch, Application Seal Conduits in Vertical or Horizontal, to Minimize the Passage of Gases and Vapors and Prevent the Passage of Flames from One Portion of the Electrical System to Another Through the Conduit, Constructional Feature Explosionproof
QTY
  • Features
Explosionproof, dust-ignition proof, raintight
Prevent passage of gases, vapors or flames from one portion of conduit system to another
Restrict any explosion to the sealed off enclosure
Prevent pressure piling within conduit system
Required in class I, division 1 and 2 locations within 18 in of enclosures containing apparatus that may cause arcs, sparks or high temperatures
Required in class I, division 1 and 2 locations where 2 in or larger conduit enters enclosure, fitting housing terminals, splices or taps
Required in class I, division 1 and 2 locations at the boundary where conduit leaves classified location
Required in class I, division 1 and 2 locations where two or more enclosures are connected by 36 in or less conduit, seal must be located within 18 in of either enclosure
Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in class I, division 2 locations
Smooth, rounded integral bushing in each hub protects conductor insulation
Accurately tapped, tapered threads for tight, rigid joints and ground continuity
Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub
UL Listed for use with Kwiko™ A Sealing Compound, also listed with certain competitors sealing cement, contact factory for details
Large opening for damming and filling
25% fill vertical and horizontal conduit sealing fittings