Appleton® EYDM-150AL EYDM Male/Female Hub Conduit Drain Sealing Fitting, 1-1/2 in, For Use With IMC/Threaded Rigid Metal Conduit

Explosion Proof Conduit Sealing Fittings
941056 MFG #: EYDM150AL
Appleton™
182.43000 / ea
  • Application: For Use With Threaded Rigid Metal Conduit And IMC
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Catalog Number: EYDM150AL
  • Connection: Tapered MNPT X Tapered FNPT
  • Country of Origin: MX
  • Currency: USD
  • EU RoHS Indicator: C
  • Gross Weight Per Pack: 0.0001 lb
  • Gross Weight per Pack Metric: 0.57
  • Gross Weight UOM Metric: kg
  • Height: 3.50 in
  • Height [Metric]: 8.8900 cm
  • Length: 6.50 in
  • Length [Metric]: 16.5100 cm
  • Standard: UL 886 (1203), UL File Number E10444, CSA C22.2 No. 30, CSA 065181, UL Listed For Class I, Groups B, C, D; Class II, Groups E, F, G; And Class III
  • Sub Brand: UNILETS
  • Type: EYDM Series 25 PCT Fill Vertical Conduit Drain Sealing Fitting With Removable Nipple
  • UNSPSC: 39121311
  • UPC 11: 78138161987
  • UPC 12: 781381619875
  • Width: 5.00 in
  • Width [Metric]: 12.7000 cm
  • Stock Status: NONSTOCK
  • Brand: Appleton™
  • Manufacturer: Appleton
  • Finish: Epoxy Powder Coated
  • Material: Almag 35 Aluminum
  • Size: 1-1/2 in
Appleton® EYDM 25% fill vertical conduit drain sealing fittings prevent the passage of gases, vapors or flames from one portion of a conduit system to another. They also restrict large amounts of ignitable gases or vapors from accumulating to confine explosive pressure. Appleton sealing fittings are explosionproof, dust-ignitionproof and raintight. They are suitable for use in class I and II locations.
QTY
  • Applications
  • Features
For Use With Threaded Rigid Metal Conduit and IMC
For preventing passage of gases, vapors or flames from one portion of conduit system to another; Required in Class I, Division 1 and 2 locations within 18 IN of enclosures containing apparatus that may cause arcs, sparks or high temperatures; Required in Class I, Division 1 and 2 locations where 2 IN or larger conduit enters enclosure, fitting housing terminals, splices or taps; Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location; Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 IN or less conduit, seal must be located within 18 IN of either enclosure; Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in Class I, Division 2 locations; Explosionproof, dust-ignitionproof, raintight; Smooth, rounded integral bushing in each hub protects conductor insulation; Accurately tapped, tapered threads for tight, rigid joints and ground continuity; U