BUR BDBMHC145003 500-4-3P-2/0-14 SE
Multi Pole Distribution Blocks
1080010
MFG #: BDBMHC145003
BURNDY®
215.87000
/ ea
- Application: Industrial control feeder, HVAC system and wire ways
- ARRA Compliant: C
- Buy American Compliant: C
- Catalog Number: BDBMHC145003
- Country of Origin: MX
- Dimensions: 3.25 in H x 5.28 in W x 5 in D
- EU RoHS Indicator: Y
- Finish: Electro-Plated Tin
- Gross Weight Per Pack: 2.0400 lb
- Gross Weight per Pack Metric: 0.92
- Gross Weight UOM Metric: kg
- Harmonization Tariff Schedule Code: 8536904000
- Height: 3.25 in
- Height [Metric]: 8.2550 cm
- Insulation: Y
- Length: 3.88 in
- Length [Metric]: 9.8552 cm
- Primary Connections|Pole: 1
- Returnable: Y
- Secondary Connection|Pole: 4
- Short Circuit Current Rating: 100 kA
- Standard: TAA Compliant (All status valid till December 2024)
- Standards: RoHS CompliantCSA CertifiedUL 1953508A
- Sub Brand: VERSI-POLE
- Temperature Rating: 194
- Type: BDB
- UNSPSC: 39121424
- UPC 11: 78181064577
- UPC 12: 781810645772
- Width: 5.28 in
- Width [Metric]: 13.4112 cm
- Stock Status: NONSTOCK
- Brand: BURNDY®
- Manufacturer: BURNDY®
- Amperage Rating: 380 A
- Material: Aluminum
- Voltage Rating: 600 VAC
- Wire Size: 4 AWG to 500 kcmil, 14 to 2/0 AWG
- Number Of Poles: 3
These Power Distribution Blocks are Listed to the Power Distribution Block Standard UL 1953. They contain the same features and characteristics as the non-Listed blocks however, these have spacing's that are suitable for installations in most industrial control panel feeder and branch circuits, HVAC systems, and Wireways (with optional cover; sold separately). They are available in one, two, or three pole configurations. An Adder is also available with optional End Barrier (sold separately), to allow user customized configurations.
- Applications
- Features
Industrial control feeder, HVAC system and wire ways |
Provided capability to create as many poles as required, Up to 30 tap conductor accommodated |
Single or dual run connections allow the user to minimize the number of connections required |
Suitable for use with aluminum or copper conductors providing maximum versatility |
Range taking designs to accommodate wire sizes up to 600 kcmil |
High short circuit rating up to 100 kA with proper fusing |
Meets spacing requirements of industrial control panel standard UL 508A (spacing of 1 in through air and 2 in over surface) |
14 to 2/0 AWG tap, 4 AWG to 500 kcmil run wire size |
Provides capability to create as many poles as required and up to 30 tap conductors accommodated |