Square D™ EZ Meter-Pak™ EZM31600GCBCMS Main Circuit Breaker Meter Center Main Unit, 120/240 VAC, 208Y/120 VAC, 1600 A, 3 ph Phase, NEMA 3R Enclosure
Meter Mains
PDW~12315328
MFG #: EZM31600GCBCMS
Square D™
0.00000
/ ea
- Alternate Catalog Number: EZM31600GCBCMS
- Application: Indoor/Outdoor Applications
- ARRA Compliant: N
- Buy American Compliant: N
- Cable Entry: OH-UG
- Catalog Number: EZM31600GCBCMS
- Country of Origin: MX
- Currency: USD
- Enclosure: Galvannealed steel;Powder Coated Steel
- EU RoHS Indicator: Y
- Gross Weight Per Pack: 1.4969 lb
- Gross Weight per Pack Metric: 149.69
- Gross Weight UOM Metric: kg
- Harmonization Tariff Schedule Code: 8536200040
- Height: 175.0000 in
- Height [Metric]: 175.0000 cm
- Item Group: 00020
- Length: 46.5000 in
- Length [Metric]: 46.5000 cm
- Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=469269205&lang=en-us
- Mounting: Wall Mounted
- Returnable: N
- Size: 68.91 in
- Standard: UL Listed
- UNSPSC: 39121102
- UPC 11: 78590163597
- UPC 12: 785901635970
- Width: 76.7000 in
- Width [Metric]: 76.7000 cm
- Brand: Square D™
- Manufacturer: Schneider Electric
- Amperage Rating: 1200 A,1600 A
- Phase: 3 phase in;3 phase out
- Type: Meter center main unit
- Voltage Rating: 120/240 V AC-208Y/120 V AC
Square D™ EZ Meter-Pak™ Meter Center Main Unit, Main Circuit Breaker, 120/240 VAC, 208Y/120 VAC, 1600 A, 3 ph, Overhead/Underground Feed, (6) 1/0 AWG to 750 kcmil, (12) 1/0 AWG to 250 kcmil Wire, Wall Mounting, NEMA 3R Enclosure, 30.19 in W x 18.31 in D x 68.91 in H Dimensions
- Applications
- Features
Indoor/Outdoor Applications |
Main Circuit Breaker;Copper busbar |
VISI-TITE™ nut and bolt make installation faster and easier by eliminating the need for special tools or time-consuming torque readings |
Circuit breaker, fusible switch and terminal box mains from 400 to 1600 A maximum |
Suitable for use as service equipment |
Unique field phase-balancing allows easy on-site changing of phase-balancing |
External mounting channels permits immediate installation with no disassembly or adjustment required |
Mounting brackets swing out of the way, allowing mounting holes to be drilled without moving the device |
Top and bottom wiring gutters allow branch circuits to exit from the top, bottom or back of the unit |
Single, double and three position meter-breaker units can be connected in any combination, providing a solution for any size application |
When installed, main terminal boxes do not protrude past adjacent meter center, complying with EUSERC's required spacing around installed meters |