Panelboards No. 67 60 degree/75 degree centrigrade Conductor Rating Suitable for use as service entrance equipment when Installed in accordance with the National Electrical Code 22kAIC RMS symmetrical, Except Where Noted 6-42 circuit devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down For a listing of CSA Listed load centers, visit www.geelectrical.com Amperage 125 A 2CCU2320
Single Phase Convertible Load Centers
1076337
MFG #: TLM2412CCU
GE
273.00000
/ ea
- Breaker Mounting: Plug-In
- Breaker Type: THQL
- Bus Rating: 125 kA
- Catalog Number: TLM2412CCU
- Country of Origin: UKN
- Dimensions: 26-3/4 in L x 16 in W x 5-1/2 in H
- Enclosure Box Size: 24-11/16 in H x 14 in W x 3-3/4 in D
- Enclosure Type: NEMA 1
- Gross Weight Per Pack: 24.5000 lb
- Mounting Type: Flush
- Number of Circuits: 24
- Number Of Spaces: 24
- Series: TLM
- Standards: ARRA CompliantBuy American Act CompliantRoHS CompliantUL ListedCSA CertifiedGSA Compliant
- Sub Brand: PowerMark Gold
- Type: 1-Phase Combination Standard
- UNSPSC: 39121101
- UPC 11: 78316411232
- UPC 12: 78316411232
- Wire Size: 6 to 2/0 AWG
- Wiring Configuration: 3-wire
- Stock Status: NONSTOCK
- Brand: GE
- Manufacturer: Industrial Connections & Solutions LLC
- Amperage Rating: 125 A
- Interrupt Rating: 65 kA
- Voltage Rating: 120/240 VAC
Panelboards No. 67 60 degree/75 degree centrigrade Conductor Rating Suitable for use as service entrance equipment when Installed in accordance with the National Electrical Code 22kAIC RMS symmetrical, Except Where Noted 6-42 circuit devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down For a listing of CSA Listed load centers, visit www.geelectrical.com Amperage 125 A 2CCU2320
- Features
UL Listed (Panelboards No. 67)- 60°/75°C Conductor RatingSuitable for use as service entrance equipment when Installed in accordance with the National Electrical Code- 22kAIC RMS symmetrical, Except WhereNoted- 6-42 circuit devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down- For a listing of CSA Listed load centers, visit www.geelectrical.com |
Suitable for use as service entrance equipment when installed in accordance with the national electrical Code® |
6 to 42-circuit devices UL listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down |
Main lugs convertible to main breaker |
For main breaker, order TQMH000, also order 2-pole THQL, THHQL or TXQL circuit breaker |
Box no 7 |
(42, 4, 24, 16, 20, 32, 40) 1/2 in spaces |
RD go schedule |