Sentron™ 5SY8310-8 Miniature Supplementary Protector, 400 VAC, 10 A, 5 kA Interrupt, 3 Poles

Supplementary Protectors
481194 MFG #: 5SY8310-8
Siemens
198.90000 / ea
  • Actuator Type: Identical wire screw connections on line and load side.
  • Alternate Catalog Number: 5SY8310-8
  • Application: SUPPLEMENTARY PROTECTION
  • ARRA Compliant: C
  • Auxiliary Contact Rating: N/A
  • Buy American Compliant: C
  • Catalog Number: 5SY8310-8
  • Connection: Identical wire screw connections on line and load side.
  • Connection Type: Screw
  • Country of Origin: DE
  • Currency: USD
  • Dimensions: 90 mm H x 54 mm W x 70 mm D
  • Enclosure Type: IP20
  • EU RoHS Indicator: C
  • Frame: 5kA V
  • Frequency Rating: 50 Hz
  • Gross Volume Per Pack: 27.97
  • Gross Volume UOM: in
  • Gross Weight Per Pack: 0.9790 lb
  • Gross Weight per Pack Metric: 0.44
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536200020
  • Height: 3.31 in
  • Height [Metric]: 8.4074 cm
  • Insulation Type: N/A
  • Length: 3.70 in
  • Length [Metric]: 9.4005 cm
  • Mounting Type: DIN Rail
  • Phase: 3 Hz
  • Power Rating: SUPPLEMENTARY PROTECTION
  • Returnable: N
  • Series: SENTRON
  • Standard: UL 1077
  • Standards: ARRA, Buy American Act and RoHS Compliant, CE Certified, cULus Listed, CSA 22.2 No. 235, EN 60898, IEC/EN 60947-2, UL 1077 File No E116386
  • Sub Brand: SENTRON
  • Temperature Rating: -25 to 45 °C
  • Trip Range: D
  • Type: Miniature
  • UNSPSC: 39121601
  • UPC 11: 75455494183
  • UPC 12: 754554941837
  • Width: 2.28 in
  • Width [Metric]: 5.7988 cm
  • Wire Size: 14 to 4 AWG
  • Stock Status: NONSTOCK
  • Brand: Siemens
  • Manufacturer: Siemens
  • Amperage Rating: 10 A
  • Interrupt Rating: 5 kA
  • Trip Type: Thermal Magnetic
  • Voltage Rating: 480 VAC
SIEMENS 5SY8310-8 SUPPLEMENTARY PROT 3-POLE 10A CURVE D
QTY
  • Applications
  • Features
SUPPLEMENTARY PROTECTION
Type D characteristic is designed for high inrush loads. Magnetic trip point - 10 to 20 times In rating. Thermal trip point - 1.13 to 1.45 protector rating.
Excellent current limiting and selectivity characteristics
Terminals offer protection against contact with fingers or the back of the hand according to the German accident prevention regulations VBG 4/BGV A2
Combined terminals enable a simultaneous connection of busbars and feeder cables
Uniform components that can be quickly mounted individually
The handle locking device virtually prevents any unauthorized operation of the handle
Rapid connection of the feeder cable in front of the busbar
Identical terminals at both sides for an optional infeed from the top or the bottom
Identical wire screw on line and load side
No tool required for mounting or dismounting
Supports a fast and comfortable removal from the assembly
Trip indication
Type D characteristic is designed for high inrush loads
35 mm DIN Rail mounting
Magnetic trip point - 10 to 20 times in rating
Thermal trip point - 1.13 to 1.45 protector rating