Sentron™ 5SY4332-7 Miniature Supplementary Protector, 480 VAC, 32 A, 5 kA Interrupt, 3 Poles

Supplementary Protectors
411560 MFG #: 5SY4332-7
Siemens
107.85000 / ea
  • Alternate Catalog Number: 5SY4332-7
  • Application: Supplementary Protectors
  • ARRA Compliant: C
  • Buy American Compliant: C
  • Catalog Number: 5SY4332-7
  • Connection Type: Screw
  • Country of Origin: DE
  • Currency: USD
  • Dimensions: 90 mm H x 54 mm W x 70 mm D
  • Enclosure Type: IP20
  • EU RoHS Indicator: C
  • Frame: 5SY4
  • Frequency Rating: 50 Hz
  • Gross Volume Per Pack: 21.17
  • Gross Volume UOM: in
  • Gross Weight Per Pack: 1.0400 lb
  • Gross Weight per Pack Metric: 0.47
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536200020
  • Height: 2.95 in
  • Height [Metric]: 7.4930 cm
  • Length: 3.50 in
  • Length [Metric]: 8.8900 cm
  • Mounting Type: DIN Rail
  • Returnable: Y
  • Standards: ARRA CompliantBuy American Act CompliantRoHS CompliantCE MarkedcULus ListedCSA 22.2 No. 235IEC/EN 60898IEC/EN 60947-2UL 1077 File No. E116386
  • Sub Brand: Controls
  • Temperature Rating: -25 to 45 °C
  • Trip Range: 36.16 to 46.4 A
  • Type: Miniature
  • UNSPSC: 39121601
  • UPC 11: 75455487639
  • UPC 12: 754554876399
  • Width: 2.05 in
  • Width [Metric]: 5.2070 cm
  • Wire Size: 14 to 4 AWG
  • Stock Status: NORMALLY STOCKED
  • Brand: Siemens
  • Manufacturer: Siemens
  • Amperage Rating: 32 A
  • Interrupt Rating: 10 kA
  • Trip Type: Thermal Magnetic
  • Voltage Rating: 480 VAC
  • Number Of Poles: 3
Miniature circuit breakers are used to protect systems and installations in buildings and for industrial applications. Used in industrial applications and plant engineering, miniature circuit breakers can be supplemented with additional components, such as auxiliary switches, fault signal contacts, shunt trips, undervoltage releases, remote controlled mechanism, RC units, and arc fault detection devices. The devices are approved for worldwide use according to IEC standards for power supply systems up to 250/440 VAC. 72 VDC per pole is permitted in DC systems.
QTY
  • Applications
  • Features
Supplementary Protectors
5SY Supplementary Protectors
Excellent current limiting and selectivity characteristics
Terminals offer protection against contact with fingers or the back of the hand according to the German accident prevention regulations VBG 4/BGV A2
Combined terminals enable a simultaneous connection of bus bars and feeder cables
Uniform components that can be quickly mounted individually
The handle locking device virtually prevents any unauthorized operation of the handle
Rapid connection of the feeder cable in front of the busbar
Identical terminals at both sides for an optional infeed from the top or the bottom
Identical wire screw-on line and load side
No tool required for mounting or dismounting
Supports a fast and comfortable removal from the assembly
Trip indication
Type C characteristic is for general device protection in control circuits
35 mm DIN-rail mounting
5 to 10 times magnetic trip point rating
1.13 to 1.45 thermal trip point protector rating