Sentron™ 5SY4201-8 5SY Miniature Circuit Breaker, 400 VAC, 1 A, 5 kA Interrupt, 2 Poles, Thermal Magnetic Trip
Supplementary Protectors
598392
MFG #: 5SY4201-8
Siemens
76.40000
/ ea
- Actuator Type: Handle
- Alternate Catalog Number: 5SY4201-8
- Application: SUPPLEMENTARY PROTECTION
- ARRA Compliant: C
- Buy American Compliant: C
- Catalog Number: 5SY4201-8
- Connection: Identical wire screw connections on line and load side.
- Connection Type: Line/Load/Screw
- Country of Origin: DE
- Currency: USD
- Dimensions: 90 mm H x 36 mm W x 76 mm D
- Enclosure Type: IP20/IP40
- EU RoHS Indicator: C
- Frame: 5SY4
- Frequency Rating: 50 Hz
- Gross Volume Per Pack: 26.64
- Gross Volume UOM: in
- Gross Weight Per Pack: 0.7500 lb
- Gross Weight per Pack Metric: 0.34
- Gross Weight UOM Metric: kg
- Harmonization Tariff Schedule Code: 8536200020
- Height: 1.60 in
- Height [Metric]: 4.0640 cm
- Length: 3.70 in
- Length [Metric]: 9.3980 cm
- Mounting Type: DIN Rail
- Returnable: Y
- Standard: UL 1077, CSA 22.2 NO. 235, CE, EN 60 898, IEC/EN 60 947-2
- Standards: ARRA CompliantBuy American Act CompliantRoHS CompliantCSA C22.2 No. 235IEC/EN 60898-1IEC/EN 60947-2CE MarkedCCC MarkedIMQ CertifiedUL 1077
- Sub Brand: SENTRON
- Temperature Rating: -25 to 55 °C
- Trip Range: 1.13 to 1.45 A
- Type: MINIATURE CIRCUIT BREAKER
- UNSPSC: 39121601
- UPC 11: 75455487596
- UPC 12: 754554875965
- Width: 4.50 in
- Width [Metric]: 11.4300 cm
- Wire Size: 14 to 4 AWG
- Stock Status: NONSTOCK
- Brand: Siemens
- Manufacturer: Siemens
- Amperage Rating: 1 A
- Interrupt Rating: 10 kA
- Trip Type: Thermal Magnetic
- Voltage Rating: 480 VAC
- Number Of Poles: 2
SIEMENS 5SY4201-8 SUPPLEMENTARY PROTECTOR 2P 1A CURVE D
- 3D Rendering URL - G_I202_XX_18131V.pdf(3D Rendering URL)
- Brochure URL - IC_Section_12_pages_9_to_10.pdf(Brochure URL)
- Catalog URL - Sentron_5SJ4108_7HG40_Catalog.pdf(Catalog URL)
- http://www.sea.siemens.com(Seller Home Page URL)
- Spec Sheet 1 URL - ID-SPE-v1-IC14_Sect15_010115.pdf(Spec Sheet 1 URL)
- Spec Sheet URL - 10991_3XMEI8POVQJ59AWB.pdf(Spec Sheet URL)
- Spec Sheet URL - 10991_BYWP4QXID3MC96EK.pdf(Spec Sheet URL)
- Spec Sheet URL - 10991_SLF8Y05RW6X924H3.pdf(Spec Sheet URL)
- Spec Sheet URL - IC14_Sect15_010115.pdf(Spec Sheet URL)
- User Manual URL - man(User Manual URL)
- Applications
- Features
SUPPLEMENTARY PROTECTION |
Type D characteristic is designed for high inrush loads. Magnetic trip point - 10 to 20 times In rating. Thermal trip point - 1.13 to 1.45 protector rating. |
Clear and visible conductor connection in front of the rear busbar facilitates controls |
The conductor is easily inserted into the terminal thanks to the large and easily accessible wiring space |
Double terminal chambers permit accommodation of two wires of different cross-sections |
Quick and easy manual removal of miniature circuit breakers from the busbar assembly, for example if connections need to be changed |
Time saving replacement of parts as busbars no longer need to be freed from adjacent devices |
For the quick and easy mounting of auxiliary switches and fault signal contacts |
Captive metal brackets on the additional components ensure the quick and easy mounting of devices on the miniature circuit breakers without the need for tools |
Class D-trip |
Type D characteristic is designed for high inrush loads |
10 to 20 times magnetic trip point rating |
1.13 to 1.45 thermal trip point protector rating |