Schneider Electric MG24539 Multi 9™ C60 Supplementary Protector, 240/415/440 VAC, 13 A, 5 kA at 480Y/277 VAC Interrupt, 3 Poles
Supplementary Protectors
115428
MFG #: MG24539
Square D™
315.00000
/ ea
- Actuator: TOGGLE mm
- Application: Distribution
- ARRA Compliant: N
- Buy American Compliant: N
- Catalog Number: MG24539
- Color: Gray
- Connection: TUNNEL TYPE TERMINAL TOP OR BOTTOM) 2.5-25 MMA² AWG 14...AWG 4) - RIGID
- Country of Origin: FR
- Dimensions: 3.19 in H x 2.13 in W x 2.87 in D
- EU RoHS Indicator: Y
- Frequency Rating: 50/60 Hz
- Gross Weight Per Pack: 0.7600 lb
- Harmonization Tariff Schedule Code: 8536200020
- Height: 81 MM
- Item Group: 00908
- Length: 73 MM
- Mounting Type: Clip-On/DIN Rail
- Operating Temperature: -30 to 70 °C
- Returnable: Y
- Standard: GB 14048.2-EN/IEC 60947-2-UL 1077-CSA C22.2 NO 235,IP20IEC 60529-IP40 MODULAR ENCLOSURE)IEC 60529,UR-CSA-CCC-IEC
- Standards: UL 1077, File No. E90509, GB 14048.2, CCC, CE, CSA C22.2 No. 235, 179014, EN/IEC 60947-2, Green Premium, RoHS, ARRA , Buy American Act Compliant
- Sub Brand: C60 UL1077,MULTI 9 C60
- Temperature Rating: -22 to 158 °F
- Type: Miniature circuit-breaker
- UNSPSC: 39121603
- UPC 11: 78590188138
- UPC 12: 785901881384
- Width: 54 mm
- Stock Status: NONSTOCK
- Brand: Square D™
- Manufacturer: Schneider Electric
- Amperage Rating: 13 A
- Interrupt Rating: 20 KA-5 KA-10 KA-6 KA-20 KA-10 KA-6 KA-10 KA-10 KA-5 KA
- Trip Type: THERMAL-MAGNETIC
- Voltage Rating: 240 V-415 V-440 V VAC
- Number Of Poles: 3
Schneider Electric MG24539 SUPPLEMENTARY PROTECTOR 480Y/277V 13A 3P,10 kA,480Y/277 V at AC-120/240 V at AC,13 A,3-Pole,480Y/277 V at AC-120/240 V at AC,D,DIN Rail (35mm),Multi 9,Multi 9,motor protection,UL 1077 Recognized, IEC 60947-2 Rated,miniature circuit-breaker
- Brochure URL - 5430777ee56dfe2ed5d0f860e8d076d8ddee6ea1.pdf(Brochure URL)
- Catalog URL - Schneider_Electric_MG17402_Catalog.pdf(Catalog URL)
- Seller Home Page URL - us(Seller Home Page URL)
- Spec Sheet URL - 0d7209d5f080f5b414278897ee92e67f3baccaf6.pdf(Spec Sheet URL)
- Tech Bulletin URL - eb20308c55d73b579c0f6338b719cdf008fd75c2.pdf(Tech Bulletin URL)
- Tech Drawing URL - XC601S(Tech Drawing URL)
- Applications
- Features
DISTRIBUTION |
ON/OFF INDICATION |
Trip free mechanism contacts cannot be held in the on position when the C60 is tripped automatically |
Positive indication of contact disconnect |
Green mechanical indication on front face of device shows that all poles are open |
Overcurrent protection for loads with high inrush currents |
Magnetic release operates between 10 and 14 times ampere rating |
Allows locking in ON-OFF position using padlock attachment |