Siemens 3RV2021-4CA15 Type 3RV20 Motor Protection Circuit Breaker, 690 VAC, 22 A, 4 kA Interrupt, 3 Poles
Motor Protection Circuit Breakers
928354
MFG #: 3RV20214CA15
Siemens
208.91000
/ ea
- Alternate Catalog Number: 3RV2021-4CA15
- ARRA Compliant: C
- Auxiliary Contact Rating: 1NO-1NC
- Buy American Compliant: C
- Catalog Number: 3RV20214CA15
- Connection Type: Screw
- Country of Origin: DE
- Currency: USD
- Dimensions: 97 mm H x 45 mm W x 97 mm D
- Enclosure Type: IP20
- EU RoHS Indicator: C
- Frame: S0
- Frequency Rating: 50/60 Hz
- Gross Volume Per Pack: 351.26
- Gross Volume UOM: in
- Gross Weight Per Pack: 0.8300 lb
- Gross Weight per Pack Metric: 0.38
- Gross Weight UOM Metric: kg
- Harmonization Tariff Schedule Code: 8536304000
- Height: 4.05 in
- Height [Metric]: 10.2870 cm
- Length: 4.10 in
- Length [Metric]: 10.4140 cm
- Mounting Type: DIN Rail/Snap-On/Threaded
- Phase: 3
- Power Rating: 18.5 kW
- Replaced Catalog Number: 3RV1021-4CA15
- Returnable: Y
- Standards: CCC CertifiedCSA CertifiedUL ListedEAC ApprovedEX ATEXIECEx CertifiedCE CertifiedVDE ApprovedRoHS CompliantABS ApprovedBureau Veritas CertifiedLloyd's RegisteredPRS CertifiedRINA CertifiedRMRS ApprovedDNV-GL ApprovedEN 60715
- Temperature Rating: -20 to 60 °C
- Trip Range: 16 to 22 A, 286 A
- UNSPSC: 39121601
- UPC 11: 66264392438
- UPC 12: 662643924381
- Width: 1.70 in
- Width [Metric]: 4.3180 cm
- Wire Size: 16 to 12 AWG, 14 to 8 AWG
- Stock Status: NORMALLY STOCKED
- Brand: Siemens
- Manufacturer: Siemens
- Amperage Rating: 22 A
- Interrupt Rating: 4 kA
- Trip Type: Thermomagnetic
- Voltage Rating: 690 VAC
- Number Of Poles: 3
SIEMENS 3RV20214CA15 MSP S0 17-22A SCREW W/AUX 1NO/1NC
- 3D Rendering URL - G_NSA0_XX_93067V.pdf(3D Rendering URL)
- http://www.sea.siemens.com(Seller Home Page URL)
- Spec Sheet URL - 10991_G2EQHKTD7X81MPR9.pdf(Spec Sheet URL)
- Spec Sheet URL - DatasheetService?format=PDF&caller=PDPS&mlfbs=3RV2021-4CA15&language=en(Spec Sheet URL)
- User Manual URL - man(User Manual URL)
- Video - https://www.youtube.com/embed/5Oq25B99HBo(Video)
- Features
Minimization of energy losses through optimization of the bimetal trip units |
Reduction of inherent power loss |
Less heating of the control cabinet |
Smaller control cabinet air conditioners can be used |
3RV2 motor starter protectors/circuit breakers are suitable for operation in IT systems (IT networks) |
5500 W at 230 VAC, 11000 W at 400 VAC, 11000 W at 500 VAC, 18500 W at 690 VAC |
100 kA at 240 VAC, 55 kA at 400 VAC, 10 kA at 500 VAC, 4 kA at 690 VAC |
16 to 22 A thermal overload release, 286 A instantaneous overcurrent release |