Siemens 3RV20110KA25 3RV2 Motor Protection Circuit Breaker With 1NO-1NC Transverse Auxiliary Switch, 690 VAC, 0.9 to 1.25 A, 3 Poles

Motor Protection Circuit Breakers
978189 MFG #: 3RV20110KA25
Siemens
147.49000 / ea
  • Alternate Catalog Number: 3RV2011-0KA25
  • ARRA Compliant: C
  • Auxiliary Contact Rating: 1NO-1NC
  • Buy American Compliant: C
  • Catalog Number: 3RV20110KA25
  • Connection Type: Spring
  • Country of Origin: DE
  • Currency: USD
  • Dimensions: 106 mm H x 45 mm W x 97 mm D
  • Enclosure Type: IP20
  • EU RoHS Indicator: C
  • Frame: S00
  • Frequency Rating: 50/60 Hz
  • Gross Volume Per Pack: 328.94
  • Gross Volume UOM: in
  • Gross Weight Per Pack: 0.8100 lb
  • Gross Weight per Pack Metric: 0.37
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536304000
  • Height: 4.25 in
  • Height [Metric]: 10.7950 cm
  • Length: 4.15 in
  • Length [Metric]: 10.5410 cm
  • Mounting Type: DIN Rail/Snap-On/Threaded
  • Phase: 3
  • Power Rating: 750 W
  • Replaced Catalog Number: 3RV10110KA25
  • Returnable: Y
  • Standards: CCC CertifiedCSA CertifiedUL ListedEAC ApprovedEX ATEXIECEx CertifiedCE CertifiedVDE ApprovedRoHS CompliantABS ApprovedBureau Veritas CertifiedLloyd's RegisteredPRS CertifiedRINA CertifiedRMRS ApprovedDNV-GL ApprovedEN 60715
  • Temperature Rating: -20 to 60 °C
  • Trip Range: 0.9 to 1.25 A, 16 A
  • UNSPSC: 39121601
  • UPC 11: 66264392176
  • UPC 12: 662643921762
  • Width: 1.50 in
  • Width [Metric]: 3.8100 cm
  • Wire Size: 20 to 12 AWG
  • Stock Status: NONSTOCK
  • Brand: Siemens
  • Manufacturer: Siemens
  • Amperage Rating: 1.25 A
  • Interrupt Rating: 100 kA
  • Trip Type: Thermomagnetic
  • Voltage Rating: 690 VAC
  • Number Of Poles: 3
The SIRIUS 3RV2 motor starter protectors/circuit breakers are compact, current limiting motor starter protectors/circuit breakers which are optimized for load feeders. The motor starter protectors/circuit breakers are used for switching and protecting three-phase motors of up to 55/45 kW at 400 VAC and for other loads with rated currents of up to 100 A.
QTY
  • Features
Minimization of energy losses through optimization of the bimetal trip units
Reduction of inherent power loss
Less heating of the control cabinet
Smaller control cabinet air conditioners can be used
3RV2 motor starter protectors/circuit breakers are suitable for operation in IT systems (IT networks)
180 W at 230 VAC, 370 W at 400 VAC, 370 W at 500 VAC, 750 W at 690 VAC
100 kA at 240 VAC, 100 kA at 400 VAC, 100 kA at 500 VAC, 100 kA at 690 VAC
0.9 to 1.25 A thermal overload release, 16 A instantaneous overcurrent release