Siemens 3RV2011-1DA15 Type 3RV2 Motor Protection Circuit Breaker, 690 VAC, 3.2 A, 10 kA Interrupt, 3 Poles

Motor Protection Circuit Breakers
580781 MFG #: 3RV20111DA15
Siemens
152.87000 / ea
  • Alternate Catalog Number: 3RV2011-1DA15
  • Application: Used as Manual Motor Controller and in Group Installation
  • ARRA Compliant: C
  • Auxiliary Contact Rating: 1NO-1NC
  • Buy American Compliant: C
  • Catalog Number: 3RV20111DA15
  • Connection: screw-type terminals
  • Connection Type: Screw
  • Country of Origin: DE
  • Currency: USD
  • Dimensions: 97 mm H x 45 mm W x 97 mm D
  • Enclosure Type: IP20
  • Environmental Conditions: 80 -50 C
  • EU RoHS Indicator: C
  • Frame: S00
  • Frequency Rating: 50/60 Hz
  • Gross Volume Per Pack: 31.19
  • Gross Volume UOM: in
  • Gross Weight Per Pack: 0.8000 lb
  • Gross Weight per Pack Metric: 0.36
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536304000
  • Height: 4.02 in
  • Height [Metric]: 10.2108 cm
  • Length: 4.02 in
  • Length [Metric]: 10.2108 cm
  • Mounting Type: DIN Rail/Snap-On/Threaded
  • Operating Temperature: 60 to -20 °C
  • Phase: 3
  • Power Rating: 2.2 kW
  • Returnable: Y
  • Standard: CE / UL / CSA / CCC
  • Standards: CCC CertifiedCSA CertifiedUL ListedEAC ApprovedEX ATEXIECEx CertifiedCE CertifiedVDE ApprovedRoHS CompliantABS ApprovedBureau Veritas CertifiedLloyd's RegisteredPRS CertifiedRINA CertifiedRMRS ApprovedDNV-GL ApprovedEN 60715
  • Sub Brand: Sirius
  • Temperature Rating: -20 to 60 °C
  • Trip Range: 2.2 to 3.2 A, 42 A
  • Type: Type 3RV2
  • UNSPSC: 39121601
  • UPC 11: 66264392194
  • UPC 12: 662643921946
  • Width: 1.93 in
  • Width [Metric]: 4.9022 cm
  • Wire Size: 18 to 14 AWG, 12 AWG
  • Stock Status: NONSTOCK
  • Brand: Siemens
  • Manufacturer: Siemens
  • Amperage Rating: 3.2 A
  • Interrupt Rating: 10 kA
  • Trip Type: Thermomagnetic
  • Voltage Rating: 690 VAC
  • Number Of Poles: 3
Siemens 3RV20111DA15 CIRCUIT-BREAKER SZ S00, FOR MOTOR PROTEC
QTY
  • Applications
  • Features
Used as Manual Motor Controller and in Group Installation
MSP?s are UL approved as Self Protected Combination Motor Controllers
Minimization of energy losses through optimization of the bimetal trip units
Reduction of inherent power loss
Less heating of the control cabinet
Smaller control cabinet air conditioners can be used
3RV2 motor starter protectors/circuit breakers are suitable for operation in IT systems (IT networks)
550 W at 230 VAC, 1100 W at 400 VAC, 1500 W at 500 VAC, 2200 W at 690 VAC
100 kA at 240 VAC, 100 kA at 400 VAC, 100 kA at 500 VAC, 10 kA at 690 VAC
2.2 to 3.2 A thermal overload release, 42 A instantaneous overcurrent release