Square D™ Mag-Gard™ GJL36015M03 Motor Circuit Protector, 600Y/347 VAC, 15 A, 65 kA at 480 VAC Interrupt, 3 Poles, Magnetic Trip

Motor Circuit Protectors
323972 MFG #: GJL36015M03
Square D™
1089.00000 / ea
  • Alternate Catalog Number: GJL36015M03
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Catalog Number: GJL36015M03
  • Connection Type: Lug
  • Country of Origin: US
  • Current Rating: 15 A
  • EU RoHS Indicator: Y
  • Frame: G
  • Gross Volume Per Pack: 129.87
  • Gross Volume per Pack Metric: 2128.18
  • Gross Weight Per Pack: 2.1800 lb
  • Gross Weight per Pack Metric: 1.05
  • Gross Weight UOM Metric: kg
  • Height: 3.70 in
  • Height [Metric]: 9.3980 cm
  • Item Group: 00924
  • Length: 6.50 in
  • Length [Metric]: 16.5100 cm
  • Material Composition Declaration: https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=export&pid=423259652&lang=en-us
  • Returnable: N
  • Series: GJL
  • Standard: CSA;UL Recognized
  • Temperature Rating: -15 to 158 °F
  • Trip Range: 45 to 165 A
  • Type: MOTOR CIRCUIT PROTECTOR
  • UNSPSC: 39121601
  • UPC 11: 78590179360
  • UPC 12: 785901793601
  • Warranty Description: Contractual Warranty: 18 months
  • Width: 5.40 in
  • Width [Metric]: 13.7160 cm
  • Wire Size: 8 to 1/0 AWG Al, 14 to 1/0 AWG Cu
  • Stock Status: NONSTOCK
  • Brand: Square D™
  • Manufacturer: Schneider Electric
  • Amperage Rating: 15 A
  • Interrupt Rating: 65 kA at 480 VAC
  • Trip Type: Magnetic
  • Voltage Rating: 347/600 VAC
  • Number Of Poles: 3
Square D GJL36015M03 by Schneider Electric MOTOR CIRCUIT PROTECTOR 600Y/347V 15A,-13F and 158F (-25 C and +70 C),15A,3,45A to 165A,50/60Hz,600Y/347Vac,G-Frame,Lugs (both ends) #8 to #1/0 AWG(Al) #14 to #1/0 AWG(Cu),Motor Circuit Protector,Provide motor circuit protection when installed as part of a UL Listed combination controller having motor overload protection,UL Recognized - CSA Certified,Unit Mount
QTY
  • Features
PROVIDE MOTOR CIRCUIT PROTECTION WHEN INSTALLED AS PART OF A UL LISTED COMBINATION CONTROLLER HAVING MOTOR OVERLOAD PROTECTION
Mag-Loc™ allows to adjust magnetic trip setting between 3 and 11 times the rated current
UL magnetic trip setting tolerances are -20% and +30% from the nominal value
Tamper-resistant cover seal provided for trip settings
Flexible design and can be used with versatile handle operating mechanisms
Extensive selection of snap-in field installable accessories same as the equivalent GJL circuit breaker
Instantaneous-trip magnetic-only circuit breakers ranging from 3 to 75 A