Sentron™ 5SY6302-7 5SY Miniature Circuit Breaker, 400 VAC, 2 A, 5 kA Interrupt, 3 Poles, Thermal Magnetic Trip
Miniature Circuit Breakers
802309
MFG #: 5SY6302-7
Siemens
87.12000
/ ea
- Actuator Type: Handle
- Alternate Catalog Number: 5SY6302-7
- Application: SUPPLEMENTARY PROTECTION
- ARRA Compliant: C
- Buy American Compliant: C
- Catalog Number: 5SY6302-7
- Connection: Identical wire screw connections on line and load side.
- Connection Type: Screw
- Country of Origin: DE
- Currency: USD
- Dimensions: 90 mm H x 54 mm W x 76 mm D
- Enclosure Type: IP20/IP40
- EU RoHS Indicator: C
- Frequency Rating: 50 Hz
- Gross Volume Per Pack: 12.67
- Gross Volume UOM: in
- Gross Weight Per Pack: 0.9700 lb
- Gross Weight per Pack Metric: 0.44
- Gross Weight UOM Metric: kg
- Harmonization Tariff Schedule Code: 8536200020
- Height: 0.9000 in
- Height [Metric]: 2.2860 cm
- Length: 4.4000 in
- Length [Metric]: 11.1760 cm
- Material: N/A
- Mounting Type: DIN Rail
- Returnable: Y
- Series: 5SY
- Standard: UL 1077, CSA 22.2 NO. 235, CE, EN 60 898, IEC/EN 60 947-2
- Standards: CSA C22.2 No. 235IEC/EN 60898-1/IEC/EN 60947-2CE CertifiedCCC CertifiedIMQ CertifiedUL 1077
- Sub Brand: SENTRON
- Temperature Rating: -25 to 55 °C
- Trip Range: 1.13 to 1.45 A
- Type: MINIATURE CIRCUIT BREAKER
- UNSPSC: 39121601
- UPC 11: 75455493766
- UPC 12: 754554937663
- Width: 3.2000 in
- Width [Metric]: 8.1280 cm
- Wire Size: 14 to 4 AWG
- Stock Status: NONSTOCK
- Brand: Siemens
- Manufacturer: Siemens
- Amperage Rating: 2 A
- Interrupt Rating: 5 kA
- Trip Type: Thermal Magnetic
- Voltage Rating: 400 VAC
- Number Of Poles: 3
SIEMENS 5SY6302-7 SUPPLEMENTARY PROTECTOR 2P 1A CURVE CSUP
- 3D Rendering URL - G_I202_XX_18134V.pdf(3D Rendering URL)
- Catalog URL - Sentron_5SJ4108_7HG40_Catalog.pdf(Catalog URL)
- Spec Sheet URL - 10991_3IRBWV5N0G68AMEH.pdf(Spec Sheet URL)
- Spec Sheet URL - 10991_JFCH9Z38D06RN54E.pdf(Spec Sheet URL)
- Spec Sheet URL - 10991_E67T2V5WDLPK43CO.pdf(Spec Sheet URL)
- http://www.sea.siemens.com(Seller Home Page URL)
- User Manual URL - man(User Manual URL)
- Applications
- Features
SUPPLEMENTARY PROTECTION |
Type C characteristic is for general device protection in control circuits. Magnetic trip point - 5 to 10 times In rating. Thermal trip point - 1.13 to 1.45 protector rating. |
Clear and visible conductor connection in front of the rear busbar facilitates controls |
The conductor is easily inserted into the terminal thanks to the large and easily accessible wiring space |
Double terminal chambers permit accommodation of two wires of different cross-sections |
Quick and easy manual removal of miniature circuit breakers from the busbar assembly, for example if connections need to be changed |
Time-saving replacement of parts as busbars no longer need to be freed from adjacent devices |
For the quick and easy mounting of auxiliary switches and fault signal contacts |
Captive metal brackets on the additional components ensure the quick and easy mounting of devices on the miniature circuit breakers without the need for tools |
Class C trip |