Sentron™ 5SY4304-8 5SY Miniature Circuit Breaker, 400 VAC, 4 A, 5 kA Interrupt, 3 Poles, Thermal Magnetic Trip

Miniature Circuit Breakers
399267 MFG #: 5SY4304-8
Siemens
100.29000 / ea
  • Actuator Type: Handle
  • Alternate Catalog Number: 5SY4304-8
  • Application: SUPPLEMENTARY PROTECTION
  • ARRA Compliant: C
  • Buy American Compliant: C
  • Catalog Number: 5SY4304-8
  • Connection: Identical wire screw connections on line and load side.
  • Connection Type: Screw
  • Country of Origin: DE
  • Currency: USD
  • Dimensions: 90 mm H x 54 mm W x 76 mm D
  • Enclosure Type: IP20/IP40
  • EU RoHS Indicator: C
  • Frequency Rating: 50 Hz
  • Gross Volume Per Pack: 143.14
  • Gross Volume UOM: in
  • Gross Weight Per Pack: 1.0100 lb
  • Gross Weight per Pack Metric: 0.46
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536200020
  • Height: 3.1500 in
  • Height [Metric]: 8.0010 cm
  • Length: 2.0000 in
  • Length [Metric]: 5.0800 cm
  • Mounting Type: DIN Rail
  • Returnable: Y
  • Series: 5SY
  • Standard: UL 1077, CSA 22.2 NO. 235, CE, EN 60 898, IEC/EN 60 947-2
  • Standards: CSA C22.2 No. 235IEC/EN 60898-1/IEC/EN 60947-2CE CertifiedCCC CertifiedIMQ CertifiedUL 1077
  • Sub Brand: SENTRON
  • Temperature Rating: -25 to 55 °C
  • Trip Range: 1.13 to 1.45 A
  • Type: MINIATURE CIRCUIT BREAKER
  • UNSPSC: 39121601
  • UPC 11: 75455487647
  • UPC 12: 754554876474
  • Width: 3.6500 in
  • Width [Metric]: 9.2710 cm
  • Wire Size: 14 to 4 AWG
  • Stock Status: NORMALLY STOCKED
  • Brand: Siemens
  • Manufacturer: Siemens
  • Amperage Rating: 4 A
  • Interrupt Rating: 5 kA
  • Trip Type: Thermal Magnetic
  • Voltage Rating: 400 VAC
  • Number Of Poles: 3
SIEMENS 5SY4304-8 SUPPLEMNTRY PROTECTOR
QTY
  • Applications
  • Features
SUPPLEMENTARY PROTECTION
Type D characteristic is designed for high inrush loads. Magnetic trip point - 10 to 20 times In rating. Thermal trip point - 1.13 to 1.45 protector rating.
Clear and visible conductor connection in front of the rear busbar facilitates controls
The conductor is easily inserted into the terminal thanks to the large and easily accessible wiring space
Double terminal chambers permit accommodation of two wires of different cross-sections
Quick and easy manual removal of miniature circuit breakers from the busbar assembly, for example if connections need to be changed
Time-saving replacement of parts as busbars no longer need to be freed from adjacent devices
For the quick and easy mounting of auxiliary switches and fault signal contacts
Captive metal brackets on the additional components ensure the quick and easy mounting of devices on the miniature circuit breakers without the need for tools
Class D trip