Siemens 3RV2 Motor Protection Circuit Breaker, 690 VAC, 5.5 to 8 A, 4 kA Interrupt, 3 Poles, Magnetic Trip
Equipment Protection Circuit Breakers
879335
MFG #: 3RV24111HA10
Siemens
137.54000
/ ea
- Alternate Catalog Number: 3RV2411-1HA10
- ARRA Compliant: C
- Buy American Compliant: C
- Catalog Number: 3RV24111HA10
- Connection Type: Screw
- Country of Origin: DE
- Currency: USD
- Dimensions: 97 mm H x 45 mm W x 97 mm D
- Enclosure Type: IP20
- EU RoHS Indicator: C
- Frame: S00
- Frequency Rating: 50/60 Hz
- Gross Volume Per Pack: 159.12
- Gross Volume UOM: in
- Gross Weight Per Pack: 0.7000 lb
- Gross Weight per Pack Metric: 0.32
- Gross Weight UOM Metric: kg
- Harmonization Tariff Schedule Code: 8536304000
- Height: 4.0000 in
- Height [Metric]: 10.1600 cm
- Length: 1.5000 in
- Length [Metric]: 3.8100 cm
- Mounting Type: DIN Rail/Snap-On/Threaded
- Phase: 3 pH
- Power Rating: 5.5 kW
- Replaced Catalog Number: 3RV1421-1HA10
- Returnable: Y
- Series: 3RV2
- Standards: CCC CertifiedCSA CertifiedUL ListedEAC ApprovedCE CertifiedVDE ApprovedRoHS CompliantABS ApprovedBureau Veritas CertifiedLloyd's RegisteredPRS CertifiedRINA CertifiedRMRS ApprovedDNV-GL Approved
- Temperature Rating: -20 to 60 °C
- Trip Range: 5.5 to 8 A, 163 A
- UNSPSC: 39121601
- UPC 11: 66264392241
- UPC 12: 662643922417
- Width: 3.6000 in
- Width [Metric]: 9.1440 cm
- Wire Size: 18 to 14 AWG, 12 AWG
- Stock Status: NONSTOCK
- Brand: Siemens
- Manufacturer: Siemens
- Amperage Rating: 8 A
- Interrupt Rating: 6 kA
- Trip Type: Thermomagnetic
- Voltage Rating: 690 VAC
- Number Of Poles: 3
- 3D Rendering URL - G_NSA0_XX_93049V.pdf(3D Rendering URL)
- http://www.sea.siemens.com(Seller Home Page URL)
- Spec Sheet URL - 10991_XPQDZW3VBIUN67ES.pdf(Spec Sheet URL)
- Spec Sheet URL - DatasheetService?format=PDF&caller=EGH&mlfbs=3RV2411-1HA10&language=en(Spec Sheet URL)
- Spec Sheet URL - DatasheetService?format=PDF&caller=PDPS&mlfbs=3RV2411-1HA10&language=en(Spec Sheet URL)
- User Manual URL - man(User Manual URL)
- Features
Minimization of energy losses through optimization of the bimetal trip units |
Reduction of inherent power loss |
Less heating of the control cabinet |
Smaller control cabinet air conditioners can be used |
3RV2 motor starter protectors/circuit breakers are suitable for operation in IT systems (IT networks) |
1500 W at 230 VAC, 3000 W at 400 VAC, 4000 W at 500 VAC, 5500 W at 690 VAC |
100 kA at 240 VAC, 100 kA at 400 VAC, 42 kA at 500 VAC, 6 kA at 690 VAC |
5.5 to 8 A thermal overload release, 163 A instantaneous overcurrent release |
Without auxiliary switch |