Square D™ QO120AFI QO® Arc-Fault Miniature Circuit Breaker, 120 VAC, 20 A, 10 kA Interrupt, 1 Pole

Arc-Fault Circuit Breakers
49069 MFG #: QO120AFI
Square D™
80.23000 / ea
  • Alternate Catalog Number: QO120AFI
  • Application: HACR rated
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Catalog Number: QO120AFI
  • Connection: Pressure Plate
  • Connection Type: Pressure Plate
  • Country of Origin: MX
  • Currency: USD
  • Dimensions: 4.75 in H x 0.75 in W x 2.9 in D
  • EU RoHS Indicator: Y
  • Frame: QO/100 A
  • Frequency Rating: 60 Hz
  • Gross Volume Per Pack: 30.03
  • Gross Volume per Pack Metric: 492.10
  • Gross Volume UOM: CI
  • Gross Volume UOM Metric: cm3
  • Gross Weight Per Pack: 11.6400 lb
  • Gross Weight per Pack Metric: 5.28
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536200020
  • Height: 0.3937 in
  • Height [Metric]: 9.9060 cm
  • Item Group: 06303
  • Length: 0.3937 in
  • Length [Metric]: 13.9700 cm
  • Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=398427&lang=en-us
  • Mounting Type: Plug-On
  • Operating Temperature: 40 °C
  • Phase: 1
  • Returnable: N
  • Standard: UL LISTED - CSA CERTIFIED
  • Standards: CSA 22.2 No. 5 Certified, RoHS Compliant, UL 489 Listed
  • Sub Brand: QO
  • Substitute Product Catalog Number: QO1PAF
  • Temperature Rating: 40 °C
  • Type: MINIATURE CIRCUIT-BREAKER
  • UNSPSC: 39121603
  • UPC 11: 78590130130
  • UPC 12: 785901301301
  • Upsell Product Catalog Number: QO612L100TRB
  • Warranty Description: Contractual Warranty:18 months
  • Width: 1.3970 in
  • Width [Metric]: 3.5560 cm
  • Wire Size: 12 to 8 AWG, 14 to 8 AWG
  • Stock Status: NONSTOCK
  • Brand: Square D™
  • Manufacturer: Schneider Electric
  • Amperage Rating: 20 A
  • Interrupt Rating: 10 kA
  • Trip Type: Thermal Magnetic
  • Voltage Rating: 120 VAC
  • Number Of Poles: 1
QTY
  • Applications
  • Features
HACR rated
ARC-FAULT PLUG-ON
An arc-fault circuit breaker opens the circuit and stops the arcing and high intensity heat before a fire is likely to ignite
Have special microprocessor-based arc identification to differentiate necessary operational arcs (associated with loads such as electric motors, switches and receptacles) from actual arc faults which can cause damage and fires
Differentiate true arc faults from chopped wave-forms associated with switched-mode power supplies on electrical appliances, computers and lamp dimmers
14 - 8 AWG copper, 12 - 8 AWG aluminum
K-Curve trip