Schneider Electric GVAX115 GVAX Safety undervoltage trip, 110 to 115 VAC, Screw Clamp Terminal connection

Breaker Shunt Trips
PDW~11716923 MFG #: GVAX115
Square D™
0.00000 / ea
  • Alternate Catalog Number: GVAX115
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Catalog Number: GVAX115
  • Country of Origin: US
  • Currency: USD
  • EU RoHS Indicator: Y
  • Gross Volume Per Pack: 61.02
  • Gross Volume per Pack Metric: 1000.00
  • Gross Volume UOM: CI
  • Gross Volume UOM Metric: cm3
  • Gross Weight Per Pack: 1.2000 lb
  • Gross Weight per Pack Metric: 129.50
  • Gross Weight UOM Metric: g
  • Harmonization Tariff Schedule Code: 8504508000
  • Height: 3.6000 in
  • Height [Metric]: 0.3600 cm
  • Item Group: 22367
  • Length: 8.4000 in
  • Length [Metric]: 0.8400 cm
  • Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=608056&lang=en-us
  • Returnable: N
  • Type: SAFETY UNDERVOLTAGE TRIP
  • UNSPSC: 39121601
  • Warranty Description: Contractual Warranty:18 months
  • Width: 9.5000 in
  • Width [Metric]: 0.9500 cm
  • Brand: Square D™
  • Manufacturer: Schneider Electric
QTY
  • Applications
  • Features
For motor circuit breakers GV2ME used in safety-related systems, For use with GV2ME Schneider Electric Square D GVAX115 Undervoltage releas Undervoltage release, For use with GV2ME TeSys GV electrical trip, MN undervoltage release, 110-115V AC 50Hz / 127V AC 60Hz
Set of 10
The GV2 manual starter and protector provides manual isolation, manual motor control, and thermal overcurrent protection in one compact unit
The basic motor starter GV2ME controls motors with full load currents up to 32A
The GV2P, high performance manual starter, offers a higher withstand rating and visible trip indication for convenience
The GV2P has an additional UL 508 type E rating as a stand alone self-protected manual combination starter
Single phase sensitivity
Magnetic instantaneous short-circuit protection
Test trip mechanism
The addition of an undervoltage trip enables the motor circuit-breaker to be tripped if voltage is lost
The addition of a shunt trip enables remote control of tripping
Fingersafe terminals (meets IP20 standards)
Fingersafe terminals (meets IP20 standards)
690 V AC IEC 60947-1 600 V AC UL 60947-4-1 600 V AC CSA C22.2 No 60947-4-1 ui rated insulation voltage
0.7 to 35 Un threshold tripping voltage
10 to 15 ms IEC 60947-1 operating time
100 % on-load factor
30000 cycles mechanical durability
With toxic heavy metal free