Siemens 3RX9501-2BA00 ASI PS,120/230VAC
PLC Power Supply Modules
626859
MFG #: 3RX9501-2BA00
Siemens
675.00000
/ ea
- Alternate Catalog Number: 3RX9501-2BA00
- ARRA Compliant: C
- Buy American Compliant: C
- Catalog Number: 3RX9501-2BA00
- Country of Origin: RO
- Currency: USD
- Dimensions: 125 mm H x 50 mm W x 125 mm D
- EU RoHS Indicator: C
- Gross Volume Per Pack: 72.20
- Gross Volume UOM: in
- Gross Weight Per Pack: 1.2000 lb
- Gross Weight per Pack Metric: 0.54
- Gross Weight UOM Metric: kg
- Harmonization Tariff Schedule Code: 8504409540
- Height: 2.3700 in
- Height [Metric]: 6.0198 cm
- Length: 5.6000 in
- Length [Metric]: 14.2240 cm
- Powering Capacity: 100 W
- Returnable: Y
- Specifications: 84% Efficiency, IP20, Snap-On/DIN Rail Mount
- Standards: ARRA CompliantBuy American Act CompliantRoHS CompliantCSA CertifiedUL ListedEAC CertifiedRCM CertifiedCE CertifiedABS CertifiedLloyd's RegisterPRS CertifiedRINA CertifiedASi CertifiedBUREAU VERITAS CertifiedWEEE (2012/19/EU)
- Temperature Rating: -10 to 70 °C
- Type: AS-Interface
- UNSPSC: 39122221
- UPC 11: 75455494505
- UPC 12: 754554945057
- Width: 5.4400 in
- Width [Metric]: 13.8176 cm
- Stock Status: NONSTOCK
- Brand: Siemens
- Manufacturer: Siemens
- Input Current: 6 A
- Input Voltage: 120/230 VAC
- Output Current: 2.6 A
- Output Voltage: 30 VDC
- Features
With integrated ground fault detection and AS-I data decoupling |
Integrated data decoupling as the result, AS-interface is able to convey both data and power along a single line |
Integrated ground fault detection the power supply units perform the reliable detection and signaling of ground faults according to IEC 60204-1 |
The AS-interface voltage can be disconnected automatically in the event of a ground fault |
Integrated overload detection an output overload is detected and reported over a diagnostics LED |
Diagnostics memory any ground faults or overloads on the output side are stored in a diagnostics memory until the device is reset |
Remote reset and remote signaling using relay contacts, a ground fault can be signaled and evaluated by a central controller and/or indicator light |
Diagnostics LED 3 different LED indicate the status of the AS-interface power supply locally at the power supply unit |
Ultra wide input range/2-phase connection the ultra wide input range of 120 to 500 V of the 8 A version means that the supply units can be used in virtually any network worldwide |
In addition, this version dispenses with the need for an N conductor as the device can be connected directly between 2 phases of a network |
Removable terminal blocks with spring-type connections for easy exchanging of devices, each power supply unit has three removable terminal blocks: for the input side, for the output side and for Signal/RESET connections |
With integrated overload detection with AS-interface data decoupling |