Schneider Electric BMXCPS4022 Modicon X80 Redundant Power Supply Module, 24 to 48 VDC Input, 3.3 to 24 VDC Output, 1/1.9 A Input, 1.67/5.5 Output, 18 to 40 W
PLC Power Supply Modules
PDW~12642277
MFG #: BMXCPS4022
Schneider Electric
0.00000
/ ea
- Alternate Catalog Number: BMXCPS4022
- ARRA Compliant: N
- Buy American Compliant: N
- Catalog Number: BMXCPS4022
- Control: RESET PUSH-BUTTON COLD RESTART
- Country of Origin: ID
- Currency: USD
- Display: 1 LED (Green) presence of voltages (OK);1 LED (Green) redundancy OK;1 LED (Green) power supply status
- EU RoHS Indicator: Y
- Gross Volume Per Pack: 292.00
- Gross Volume per Pack Metric: 4785.00
- Gross Weight Per Pack: 6.6000 lb
- Gross Weight per Pack Metric: 660.00
- Gross Weight UOM Metric: g
- Harmonization Tariff Schedule Code: 8504409510
- Height: 18.0000 in
- Height [Metric]: 18.0000 cm
- Item Group: 18160
- Length: 9.0000 in
- Length [Metric]: 9.0000 cm
- Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=455766267&lang=en-us
- Power Supply: 8.5 W
- Returnable: Y
- Standard: EN 61131-2-EN 61000-6-4-EN 61000-6-2-EN 61010-2-201,IP20
- Substitute Product Catalog Number: BMXXBC050K
- Type: Power supply module
- UNSPSC: 32151705
- UPC 11: 785901786702
- UPC 12: 785901786702
- Width: 25.0000 in
- Width [Metric]: 25.0000 cm
- Brand: Schneider Electric
- Manufacturer: Schneider Electric
- 360 Degree View URL - index.html?pid=11003&id=14640249360Den&ext=webp(360 Degree View URL)
- Brochure URL - 7e0216dfad8510a20e4b6372e2ef08637b8a180b.pdf(Brochure URL)
- Computer~Aided [CAD|BIM] Model URL(Computer~Aided [CAD|BIM] Model URL)
- Seller Home Page URL - us(Seller Home Page URL)
- Service Manual URL - 11003_316L25EAQUHJMIWR.pdf(Service Manual URL)
- Service Manual URL - 11003_JOUV8RGHMCTK46PE.pdf(Service Manual URL)
- Spec Sheet URL - 11003_DVZIX56BQTLS0JYA.pdf(Spec Sheet URL)
- User Manual URL - 11003_CONW3ZQ2MBJ9G7T8.pdf(User Manual URL)
- User Manual URL - files?p_enDocType=User+guide&p_File_Name=EIO0000002626.06.pdf(User Manual URL)
- Features
Redundancy information;redundancy test;temperature sensing;remaining lifetime;uptime duration;1 connector 2 alarm relay;1 connector 5 line supply, protective earth;Internal fuse not accessible primary circuit;overload protection secondary circuit;overvoltage protection secondary circuit;short-circuit protection secondary circuit |
1.67 A 24 VDC I/O module power supply and processor, 5.5 A 3.3 VDC I/O module logic power supply current at secondary voltage |
1 A at 48 VAC and 1.9 A at 24 VAC input current |