Siemens 6ES71936BP000BA1 BU Type A1 Base Unit
I/O Base Units
814342
MFG #: 6ES71936BP000BA1
Siemens
44.00000
/ ea
- Alternate Catalog Number: 6ES7193-6BP00-0BA1
- ARRA Compliant: C
- Buy American Compliant: C
- Catalog Number: 6ES71936BP000BA1
- Country of Origin: DE
- Currency: USD
- Dimensions: 117 mm H x 15 mm W x 35 mm D
- EU RoHS Indicator: C
- Finish: 117 mm H x 15 mm W x 35 mm D
- Gross Volume Per Pack: 8.66
- Gross Volume UOM: in
- Gross Weight Per Pack: 0.1000 lb
- Gross Weight per Pack Metric: 0.05
- Gross Weight UOM Metric: kg
- Harmonization Tariff Schedule Code: 8536904000
- Height: 1.1400 in
- Height [Metric]: 2.8956 cm
- Length: 4.8400 in
- Length [Metric]: 12.2936 cm
- Number Of Terminals: 18
- Output: SIMATIC ET 200SP Distributed I/O System
- Returnable: Y
- Standards: ARRA CompliantBuy American Act CompliantRoHS Compliant
- Suitable For Use With: SIMATIC ET 200SP Distributed I/O System
- Type: BU Type A1
- UNSPSC: 32151704
- UPC 11: 04089293356
- UPC 12: 040892933567
- Width: 1.5700 in
- Width [Metric]: 3.9878 cm
- Wire Clamp Type: Push-In
- Stock Status: NONSTOCK
- Brand: Siemens
- Manufacturer: Siemens
- Input Type: DC Current/Voltage
- Line Power: 10 A at 24 VDC
- Number of Embedded: 18
Siemens Base Unit, BU Type A1
- 3D Rendering URL - G_ST70_XX_97955V.pdf(3D Rendering URL)
- http://www.sea.siemens.com(Seller Home Page URL)
- Spec Sheet URL - DatasheetService?format=PDF&caller=PDPS&mlfbs=6ES7193-6BP00-0BA1&language=en(Spec Sheet URL)
- Line Drawing URL(Line Drawing URL)
- Spec Sheet 1 URL - Siemens_6ES7193_6BP20_0BA0_Specification_Sheet_1.pdf(Spec Sheet 1 URL)
- Tech Drawing URL - 10991_31LNY498PDETRS5X.pdf(Tech Drawing URL)
- User Manual URL - man(User Manual URL)
- Features
Push-in terminal |
Circuit breaker with type B or C tripping characteristic |
117 mm H x 15 mm W x 35 mm D |
Faultproof color coding of the spring NC contacts for better orientation in the terminal panel |
Replacement of I/O modules during operation without affecting the wiring |
Operation with module gaps |
Automatic coding of the I/O modules prevents destruction of the electronics if a module is accidentally inserted in the wrong slot during replacement |
Self-assembling shielded backplane bus |
Multi-layer conductor plate with shield levels for interference-free signal transmission from the terminal to the I/O module |
System integrated, space-saving shield connection for quick installation |
Self-assembling potential groups without external wiring or jumpers |
Replaceable terminal box |
Side by side latching of the bus for high mechanical and EMC loads |
Bridged to the left |
Without auxiliary terminal |