for guard open/guard closed and locked 2 LEDs (green or orange);Locking on de-energisation and unlocking on energisation of solenoid;Overvoltage protection signalling circuit |
Rectangular design |
2 entries tapped for M20 x 1.5 cable entry |
Locking on de-energisation and unlocking on energisation of solenoid electromagnet interlocking |
24 V - 20 to 10 % us solenoid rated supply voltage |
0.28 to 0.51 in 7 to 13 mm cable outer diameter |
With interlocking, locking by solenoid locking options description |
24/48 V 20 to 52 V signalling circuit voltage |
With NC contact positive opening |
1 load factor |
7 mA signalling circuit consumption |
7 mA signalling circuit consumption |
1000000 cycles mechanical durability |
03 ft/s 01 m/s minimum actuation speed |
1.64 ft/s 0.5 m/s maximum actuation speed |
50 VEN/IEC 60947-1 signalling circuit ui rated insulation voltage |
6 kV EN/IEC 60947-5-1 uimp rated impulse withstand voltage |
Overvoltage protection signalling circuit protection type |
10 A cartridge fuse gG gl short-circuit protection |
2000 N actuator forcible withdrawal rtc |
20 N minimum actuator force for extraction |