or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Ferraz Shawmut
FERRAZ MPDB66463 PDB 3P CU INTERMED
Custom_Product_Images_Illustration
Ferraz Shawmut
FERRAZ MPDB66463 PDB 3P CU INTERMED
SKU872599
MFGR #MPDB66463
Your Cost: $467.84/ea
The Next Generation Power Distribution Block (PDB). Mersen power distribution blocks provide a safe and easy method of splicing cables, splitting primary power into secondary circuits and fulfilling requirements for fixed junction tap-off points. All blocks are UL and CSA approved while meeting spacing requirements for feeder and branch circuits in conjunction with UL508A and the National Electrical Code-?. PDB options include single or dual conductor primary inputs and up to 30 secondary outputs. Specialty blocks are available allowing for up to 7 primary inputs. The MPDB series is offered in three size categories: miniature (MPDB62 and MPDB63 series), intermediate (MPDB66 and MPDB67 series), and large (MPDB68 and MPDB69 series), in both aluminum and copper. 1 wires in 6 wires out 3 poles 380 amps CU INT size.
The Next Generation Power Distribution Block (PDB). Mersen power distribution blocks provide a safe and easy method of splicing cables, splitting primary power into secondary circuits and fulfilling requirements for fixed junction tap-off points. All blocks are UL and CSA approved while meeting spacing requirements for feeder and branch circuits in conjunction with UL508A and the National Electrical Code-?. PDB options include single or dual conductor primary inputs and up to 30 secondary outputs. Specialty blocks are available allowing for up to 7 primary inputs. The MPDB series is offered in three size categories: miniature (MPDB62 and MPDB63 series), intermediate (MPDB66 and MPDB67 series), and large (MPDB68 and MPDB69 series), in both aluminum and copper. 1 wires in 6 wires out 3 poles 380 amps CU INT size.
Alternate Catalog Number MPDB66463 Application Cable splicing Splitting primary power into secondary circuits Fixed junction tap-off points ARRA Compliant X Buy American Compliant X Catalog Number MPDB66463 Color Black Conductor Range 500-#4 , #2-#14 Connection Box To Box Country of Origin MX Currency USD Dimensions 3.25 in H x 5.28 in W x 5 in D EU RoHS Indicator Y Gross Volume Per Pack 52.85 Gross Weight Per Pack 3.4000 lb Gross Weight per Pack Metric 1.54 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 8536904000 Height 3.25 in Height [Metric] 82.5500 mm Length 3.08 in Length [Metric] 78.2320 mm Mounting Direct Screw Mount Number Of Conductors 1 , 6 Number Of Poles 3 Primary Connections|Pole 1 Secondary Connection|Pole 6 Series MPDB Short Circuit Current Rating 100 kA Size 3.08 x 5.28 x 3.25 in Standard UL Listed - File E352417 CSA Certified - Class 6228 01 RoHS Compliant Standards RoHS CompliantUL File No. E352417CSA Class 6228-01, File No. 069363_0_000CE CertifiedUL94-V0 Flammability Type Open-Style Power Distribution Blocks UNSPSC 39121410 UPC 11 78200145434 UPC 12 78200145434 Width 5.28 in Width [Metric] 134.1120 mm Stock Status NONSTOCK Brand Ferraz Shawmut Manufacturer Ferraz Shawmut Amperage Rating 380 A Material Polycarbonate Voltage Rating 600 VAC Wire Size 4 AWG to 500 kcmil Cable splicing Splitting primary power into secondary circuits Fixed junction tap-off points • Adder Poles: All sizes have optional adder poles for increased flexibility and ease-of-use. Adder poles can be stacked to form multi-pole units in the field witho ut the use of tools. Adder poles allow for customization of primary and secondary wire combinations. End barriers are also available for sale, catalog numbers can be found in the catalog number selection tables for each size block • Wire Connectors: Standard aluminum and copper wire connectors are available. Aluminum connectors accept both AL or CU wire while copper connectors accept CU wire only. Connectors are all 1-piece tin-plated • Insulators: Insulators are virtually unbreakable, made of glass-filled polycarbonate. “Seethrough,” hinged safety covers are optional and provide a greater degree of safety and shock resistance where required. Hinged covers can be installed without tools • Spacings: 1 inch through air and 2 inches over surface between uninsulated live parts of opposite polarity meets requirements for feeder and branch circuit applications of UL508A • Safety Covers: Polycarbonate safety covers provide dead-front protection. One cover is needed for each pole. Each cover has a test probe hole in the center for circuit checking. Covers are optional accessories and catalog numbers can be found in the catalog selection tables for each size block Aluminum connectors accept both aluminum or copper wire while copper connectors accept copper wire only Connectors are all 1-piece tin plated Insulators are virtually unbreakable, made of glass-filled polycarbonate See-through, hinged safety covers provide a greater degree of safety and shock resistance where required Hinged covers can be installed without tools 1 in through air and 2 in over surface between uninsulated live parts of opposite polarity meets requirements for feeder and branch circuit applications of UL 508A Polycarbonate safety covers provide dead-front protection One cover is needed for each pole Each cover has a test probe hole in the center for circuit checking 4 AWG to 500 kcmil Cu line, 14 to 2 AWG Cu load
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
| Alternate Catalog Number | MPDB66463 |
| Application | Cable splicing Splitting primary power into secondary circuits Fixed junction tap-off points |
| ARRA Compliant | X |
| Buy American Compliant | X |
| Catalog Number | MPDB66463 |
| Color | Black |
| Conductor Range | 500-#4 , #2-#14 |
| Connection | Box To Box |
| Country of Origin | MX |
| Currency | USD |
| Dimensions | 3.25 in H x 5.28 in W x 5 in D |
| EU RoHS Indicator | Y |
| Gross Volume Per Pack | 52.85 |
| Gross Weight Per Pack | 3.4000 lb |
| Gross Weight per Pack Metric | 1.54 |
| Gross Weight UOM Metric | kg |
| Harmonization Tariff Schedule Code | 8536904000 |
| Height | 3.25 in |
| Height [Metric] | 82.5500 mm |
| Length | 3.08 in |
| Length [Metric] | 78.2320 mm |
| Mounting | Direct Screw Mount |
| Number Of Conductors | 1 , 6 |
| Number Of Poles | 3 |
| Primary Connections|Pole | 1 |
| Secondary Connection|Pole | 6 |
| Series | MPDB |
| Short Circuit Current Rating | 100 kA |
| Size | 3.08 x 5.28 x 3.25 in |
| Standard | UL Listed - File E352417 CSA Certified - Class 6228 01 RoHS Compliant |
| Standards | RoHS CompliantUL File No. E352417CSA Class 6228-01, File No. 069363_0_000CE CertifiedUL94-V0 Flammability |
| Type | Open-Style Power Distribution Blocks |
| UNSPSC | 39121410 |
| UPC 11 | 78200145434 |
| UPC 12 | 78200145434 |
| Width | 5.28 in |
| Width [Metric] | 134.1120 mm |
| Stock Status | NONSTOCK |
| Brand | Ferraz Shawmut |
| Manufacturer | Ferraz Shawmut |
| Amperage Rating | 380 A |
| Material | Polycarbonate |
| Voltage Rating | 600 VAC |
| Wire Size | 4 AWG to 500 kcmil |
| Cable splicing Splitting primary power into secondary circuits Fixed junction tap-off points |
| • Adder Poles: All sizes have optional adder poles for increased flexibility and ease-of-use. Adder poles can be stacked to form multi-pole units in the field witho ut the use of tools. Adder poles allow for customization of primary and secondary wire combinations. End barriers are also available for sale, catalog numbers can be found in the catalog number selection tables for each size block • Wire Connectors: Standard aluminum and copper wire connectors are available. Aluminum connectors accept both AL or CU wire while copper connectors accept CU wire only. Connectors are all 1-piece tin-plated • Insulators: Insulators are virtually unbreakable, made of glass-filled polycarbonate. “Seethrough,” hinged safety covers are optional and provide a greater degree of safety and shock resistance where required. Hinged covers can be installed without tools • Spacings: 1 inch through air and 2 inches over surface between uninsulated live parts of opposite polarity meets requirements for feeder and branch circuit applications of UL508A • Safety Covers: Polycarbonate safety covers provide dead-front protection. One cover is needed for each pole. Each cover has a test probe hole in the center for circuit checking. Covers are optional accessories and catalog numbers can be found in the catalog selection tables for each size block |
| Aluminum connectors accept both aluminum or copper wire while copper connectors accept copper wire only |
| Connectors are all 1-piece tin plated |
| Insulators are virtually unbreakable, made of glass-filled polycarbonate |
| See-through, hinged safety covers provide a greater degree of safety and shock resistance where required |
| Hinged covers can be installed without tools |
| 1 in through air and 2 in over surface between uninsulated live parts of opposite polarity meets requirements for feeder and branch circuit applications of UL 508A |
| Polycarbonate safety covers provide dead-front protection |
| One cover is needed for each pole |
| Each cover has a test probe hole in the center for circuit checking |
| 4 AWG to 500 kcmil Cu line, 14 to 2 AWG Cu load |