Most commonly used for AC operation; Range depends on sensor; 4-Wire operation; The output is rated for 250V AC maximum, and all can switch a voltage which is different than the supply as long as both AC circuits share a common neutral; Designed to handle the inrush current of AC inductive loads like motor starters and solenoids and the holding current specification of any inductive load should not exceed the 750 MILAMP output rating; Will interface directly to all AC programmable controller inputs; Contain built-in transient suppression to prevent false turn-on or damage from inductive loads and line "spikes"; Outputs of multiple power blocks may be wired in series or parallel for "AND" and "OR" logic functions" |
50/60 Hz input |
3/4 A maximum (derated to 1/2 A at 70 deg C) output |
10 A for 1 sec or 30 A for one AC cycle (non-repeating) maximum inrush |
Less than 10 VAC at full load on-state voltage drop |
Less than 100 mA off-state leakage current |
Add 8.3 millisecond to the off-time response of the scanner block |
Range depends on sensor |
Wiring chamber |
2 m length cable connection |