Appleton® N1DC75-3MS Intraground™ N1 Explosionproof Feed-Through Manual Motor Starter, 3 Poles, NEMA 3/4X/7CD/12 Enclosure
Hazardous Location Motor Starters
395968
MFG #: N1DC75-3MS
Appleton™
1304.34000
/ ea
- ARRA Compliant: N
- Buy American Compliant: N
- Catalog Number: N1DC75-3MS
- Country of Origin: MX
- Currency: USD
- EU RoHS Indicator: C
- Gross Weight Per Pack: 3.7500 lb
- Gross Weight per Pack Metric: 1.70
- Gross Weight UOM Metric: kg
- Height: 6.30 in
- Height [Metric]: 16.0020 cm
- Length: 7.30 in
- Length [Metric]: 18.5420 cm
- Standards: UL 508, 698, 1203, File No. E76550, NEC Class I, Division 1 and 2, Groups C, D
- UNSPSC: 39121521
- UPC 11: 78138151352
- UPC 12: 781381513524
- Width: 7.10 in
- Width [Metric]: 18.0340 cm
- Stock Status: NONSTOCK
- Brand: Appleton™
- Manufacturer: Appleton
- Features
Non-metallic construction with metal imbedded grounding grid |
No need to install special wires and parts for grounding |
Special grounding wire furnished with each box provides safe grounding when cover is removed |
Unique labyrinth path construction assures flame tight joint between body and cover |
Silicone gasket, specially designed for the labyrinth path joint, prevents entrance of moisture without interfering with the venting of cooled hazardous gases and vapors |
High strength thermoplastic polyetherimide, together with thick walls (5/16 in) and sound structural design (rounded corners) provides superior resistance to impact and crushing |
Excellent resistance to ultraviolet light and water |
Excellent resistance to attack by fungi and mold |
Excellent conduit connection strength |
Superior flammability resistance |
Typical mechanical properties of 24500 psi tensile strength, 3% elongation at break, 33000 psi flexural strength and 1200000 psi flexural modulus |
Without overload protection |
Typical mechanical properties of 24500 psi tensile strength, 3% elongation at break, 33000 psi flexural strength and 1200000 psi flexural modulus |
Not suitable for ethylene dichloride and partially halogenated hydrocarbons, sealing fittings must be field installed adjacent to enclosure on all conduit runs |
With sealing fittings installed at each conduit entrance |
The N1 series enclosures withstood a hydrostatic test of four times the maximum internal explosion pressure that could be developed from a gas or vapor explosion |
Listed for use in class I, Groups C and D, Division 1 and 2 atmospheres, such as diethyl ether, methyl ethyl keytone, acetone, toluene, number 3 fuel oil, ammonium hydroxide (20%), benzene, regular unleaded gas, ethyl acetate, hexane and methanol |
1/2 or 3/4 in hub |
30% glass reinforced thermoplastic polyetherimide material |
3 hp at 120 VAC, 7.5 hp at 240 Vac, 15 hp at 480/600 VAC |