or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Schneider Electric 70S2-04-B-03-V 70S2 Series Compact, 3 A, SPST 1 Form A contact
SKUPDW~13029717
MFGR #70S2-04-B-03-V
Your Cost: $39.79/ea
Schneider Electric 70S2-04-B-03-V, Compact, 70S2 Series, 3 A, SPST (1 Form A) Contact Form, PCB Mounting, -40 to 185 deg F, 1.02 in H x 0.37 in W x 1.23 in D Dimensions
Schneider Electric 70S2-04-B-03-V, Compact, 70S2 Series, 3 A, SPST (1 Form A) Contact Form, PCB Mounting, -40 to 185 deg F, 1.02 in H x 0.37 in W x 1.23 in D Dimensions
Catalog Number 70S2-04-B-03-V Currency USD Gross Weight Per Pack 0.0400 lb Gross Weight per Pack Metric 18.14 Gross Weight UOM Metric g Height 1.0160 in Item Group 21127 Length 4.3180 in Returnable Y Series 70S2 Width 3.3020 in Brand Square D™ Manufacturer Schneider Electric No moving parts which extends service life Vibration resistant which maintains a constant state Front-facing LED for instant indication of line voltage High breaking capacities 24 to 140 V AC output voltage 1 to 19 mA at 3 to 32 V DC typical input current limits Reverse polarity 3 V DC control protection type Triac outputZero voltage switching switching device 400 V maximum peak voltage <1.6 V on-state AC voltage drop <1.6 V on-state AC voltage drop 25 deg C/W thermal resistance 6 mA at off-state leakage current 300 V/ms off-state at maximum rated voltage dv/dt 8.33 ms (turn-on, turn-off) response time 3750 V minimum dielectric strength 1.23 oz (35 g) product weight
content loaded
content loaded
content loaded
- Attributes
- Features
- Substitute Products
| Catalog Number | 70S2-04-B-03-V |
| Currency | USD |
| Gross Weight Per Pack | 0.0400 lb |
| Gross Weight per Pack Metric | 18.14 |
| Gross Weight UOM Metric | g |
| Height | 1.0160 in |
| Item Group | 21127 |
| Length | 4.3180 in |
| Returnable | Y |
| Series | 70S2 |
| Width | 3.3020 in |
| Brand | Square D™ |
| Manufacturer | Schneider Electric |
| No moving parts which extends service life |
| Vibration resistant which maintains a constant state |
| Front-facing LED for instant indication of line voltage |
| High breaking capacities |
| 24 to 140 V AC output voltage |
| 1 to 19 mA at 3 to 32 V DC typical input current limits |
| Reverse polarity 3 V DC control protection type |
| Triac outputZero voltage switching switching device |
| 400 V maximum peak voltage |
| <1.6 V on-state AC voltage drop |
| <1.6 V on-state AC voltage drop |
| 25 deg C/W thermal resistance |
| 6 mA at off-state leakage current |
| 300 V/ms off-state at maximum rated voltage dv/dt |
| 8.33 ms (turn-on, turn-off) response time |
| 3750 V minimum dielectric strength |
| 1.23 oz (35 g) product weight |