Dongan 85-LM025 85 Low Voltage Transformer, 240x480 VAC Primary, 24/48 VDC Secondary, 0.5 kVA, 50/60 Hz, 1 Phase
Transformers, Low Voltage Signaling
PDW~50311
MFG #: 85-LM025
Dongan
205.40000
/ ea
- Catalog Number: 85-LM025
- Connection Type: Lead Wire
- Country of Origin: USA
- Dimensions: 12 in H x 4.87 in W x 5.25 in D
- Enclosure Type: NEMA 3R
- Gross Weight Per Pack: 19.0000 lb
- Maximum Amperage Rating: 2/1/20.8/10.4 A
- Mounting Type: Wall
- Series: 85
- Standards: UL/cUL Listed
- Type: Low Voltage
- UNSPSC: 39121025
- UPC 11: 78249035725
- Stock Status: NONSTOCK
- Brand: Dongan
- Manufacturer: Dongan Electric
- Frequency Rating: 50/60 Hz
- Phase: 1
- Power Rating: 0.5 kVA
- Primary Voltage: 240x480 VAC
- Secondary Voltage: 24/48 VDC
Dongan Transformer, Low Voltage, Series: 85, 240x480 VAC Primary, 24/48 VDC Secondary, 0.5 kVA, 50/60 Hz, 1 Phase, 2/1/20.8/10.4 A Maximum, Lead Wire, Wall Mount, 180 deg C, NEMA 3R, 12 in H x 4.87 in W x 5.25 in D
- Features
Load Amps At Buck - Decrease Voltage: 22.9 AMP At 230 V Load And 253 V Line, 12.2 AMP At 230 V Load And 277 V Line, 22.9 AMP At 240 V Load And 264 V Line, 12.5 AMP At 240 V Load And 288 V Line, 21.8 AMP At 480 V Load And 504 V Line, 11.4 AMP At 480 V Load And 528 V Line; Load Amps At Boost - Increase Voltage: 10.4 AMP At 240 V Load And 192 V Line, 10.4 AMP At 240 V Load And 200 V Line, 20.8 AMP At 240 V Load And 216 V Line, 20.8 AMP At 240 V Load And 218 V Line, 10.4 AMP At 480 V Load And 432 V Line, 10.5 AMP At 480 V Load And 437 V Line, 20.8 AMP At 480 V Load And 456 V Line, 20.6 AMP At 480 V Load And 457 V Line; Line Fuse At Buck - Decrease Voltage: 30 V At 230 V Load And 253 V Line, 15 V At 230 V Load And 277 V Line, 30 V At 240 V Load And 264 V Line, 15 V At 240 V Load And 288 V Line, 30 V At 480 V Load And 504 V Line, 15 V At 480 V Load And 528 V Line; Kva |
Electrostatic shield between primary and secondary windings provides cleaner output voltage and helps to reduce spikes and transients |
Epoxy-silica encapsulated core and coil provides a transformer particularly well suited for harsh commercial and industrial applications |
Copper windings and copper lead wire terminations used throughout |
UL class 180 deg C insulation system with 115 deg C temperature rise at a maximum ambient of 40 deg C |
Wall mount enclosure suitable for indoor or outdoor use |
May be used in banks of 2 or 3 units for standard three phase voltages and nonstandard, open delta autotransformer/applications |
Multiple knockouts provide convenient conduit entry and exit locations through the front and bottom access wiring compartment covers |
Ground studs provided for bonding compatibility with both metallic and nonmetallic conduit |